The / commands are also available in the contextual menu of the controllers.
The command allows you to deactivate the device user rights management in your controller. Upon executing this command, a dialog box is displayed requesting you to specify a folder on your EcoStruxure Machine Expert PC or selecting the controller to save a backup of the user rights that are active. For saving the file to the PC, you must enter a password. If you confirm the dialog box with OK, you are disconnected from the controller and the user is logged off from the device user management.
In order to help prevent unauthorized access to your controller, keep the device user rights management function activated. If you ensure that your machine or process is not accessible to unauthorized personnel, you can deactivate the function by executing the command. Your individual credentials are required for this procedure.
| WARNING | |
|---|---|
The command re-enables the device user rights management that was previously disabled. A dialog box is displayed requesting you to select whether to restore the device user rights settings from the controller or from the PC, requiring the password that was assigned when the user rights management was disabled.
The Modicon M241 Logic Controller, Modicon M251 Logic Controller, and the Modicon M262 Logic/Motion Controller allow you to disable and enable the device user rights management via the embedded webserver:
Consult the Programming Guide specific to your controller for further information:
The simulation device in EcoStruxure Machine Expert Logic Builder has own user rights that can differ from those that are defined in the real controller.
In order to deactivate user rights in the simulation device, proceed as follows:
|
Step |
Action |
|---|---|
|
1 |
Close all instances of EcoStruxure Machine Expert Logic Builder. |
|
2 |
Close all instances of Vijeo-Designer. |
|
3 |
Remove the folder c:\ProgramData\CODESYS\Simulation. Result: The simulation device is reset to the default settings. |