This procedure helps you through the installation and startup of your TM5 field bus interface.
Step |
Action |
Comment |
---|---|---|
1 |
Unpack your field bus interface module and verify the contents of the package. |
Package content: oInstruction Sheet ofield bus interface module |
2 |
Unpack: oThe bus base of your field bus interface othe Interface Power Distribution Module (IPDM) oThe terminal block |
For more information, refer to the Physical Description. |
3 |
Assemble all separate parts together. |
For more information, refer to the Field Bus Interface Installation. |
4 |
Choose an appropriate cabinet and DIN rail and install your field bus interface on the DIN rail. |
For more information, refer to the DIN Rail Installation and Enclosing the TM5 System. |
5 |
Install the expansion modules. |
For more information, refer to the Slices Installation or Compact I/O Installation. |
6 |
Connect the communication field bus interface |
For more information, refer to TM5NEIP1 Wiring Diagram. |
7 |
Connect your devices to the inputs and outputs. |
For more information refer to TM5 Hardware Guides. |
8 |
Connect the external 24 Vdc power source(s) to the Interface Power Distribution Module (IPDM) and any optional Power Distribution Modules (PDM). |
For more information, refer to IPDM Wiring Diagram. |
9 |
Verify all connections. |
— |