Step |
Action |
|---|---|
|
1 |
In the in Logic Builder, right-click the node (SLC) and select from the context menu.
NOTE: If you are starting Machine Expert - Safety for the first time after the software installation but you did not enter a license key for permanent software activation, you must register once to get a trial version activation. For that purpose, follow the instructions on the screen.
Result: Machine Expert - Safety is started and the safety-related project is generated automatically. The dialog appears. |
|
2 |
You must create a password for the project (access) levels Development and Commissioning of the tool as you are opening the safety-related project the first time in Machine Expert - Safety. (The lowest access level Maintenance does not require a password.) The complete functional range from programming up to debugging is provided at Development level. Refer to the chapter Password Protection for Projects and Safety Logic Controller in the EcoStruxure Machine Expert - Safety - User Guide for detailed information on password protection. |
|
3 |
Confirm the safety-related devices by marking the appropriate check boxes and clicking . |
When opening a safety-related project, the list of safety-related devices in the standard project is synchronized with the device list contained in the safety-related project. This device synchronization is continuously repeated as long as the project remains open in Machine Expert - Safety. This way, any modification in the standard project is recognized and transferred to the safety-related project.
If you reject the modifications in the device list, Machine Expert - Safety is closed.
Device synchronization is only possible if you are logged on at Development level in Machine Expert - Safety.
When applying modifications in the bus configuration to the safety-related project, each modification is entered in the Project Event log and can be traced afterwards.