The feedback interface provides status values for the reference motion parameters and the actual motion values of a carrier.
|
Name |
Data type |
Unit |
Value range |
Accessing |
Description |
|---|---|---|---|---|---|
|
ifFeedbackChannelA |
– |
– |
Read |
Access to the feedback interface IF_CarrierFeedbackMotionValuesChannelA that provides channel A status values for the superimposed part of a carrier movement. |
|
|
ifFeedbackChannelB |
– |
– |
Read |
Access to the feedback interface IF_CarrierFeedbackMotionValuesChannelB that provides channel B status values for the superimposed part of a carrier movement. |
|
|
ifFeedbackChannelC |
– |
– |
Read |
Access to the feedback interface IF_CarrierFeedbackMotionValuesChannelC that provides channel C status values for the superimposed part of a carrier movement. |
|
|
lrCurrent |
LREAL |
mA |
– |
Read |
Indicates the current of a carrier. |
|
lrPosition |
LREAL |
mm |
– |
Read |
Indicates the position of a carrier. |
|
lrRefAcceleration |
LREAL |
mm/s2 |
– |
Read |
Indicates the reference acceleration of a carrier. |
|
lrRefPosition |
LREAL |
mm |
– |
Read |
Indicates the reference position of a carrier. |
|
lrRefTrackposition |
LREAL |
mm |
0.0 ≤ lrRefTrackposition ≤ lrTrackLength(1) |
Read |
Indicates the reference track position of a carrier. |
|
lrRefVelocity |
LREAL |
mm/s |
– |
Read |
Indicates the reference velocity of a carrier. |
|
lrVelocity |
LREAL |
mm/s |
– |
Read |
Indicates the velocity of a carrier. |
|
(1) For more information on the track length, refer to lrTrackLength. |
|||||