Using the library with other versions of software or firmware may have results other than described in the present documentation.
| WARNING | |
|---|---|
EcoStruxure Machine Expert V1.2.6
Version identification
|
Description |
Version |
|---|---|
|
Modicon M262 Motion Controller (TM262M25MESS8T and TM262M35MESS8T) |
V5.0.4.83 |
Version identification
|
Description |
Version |
|---|---|
|
EcoStruxure Machine Expert |
V1.2.6 |
For the related hardware/firmware information, see above.
The Modicon M262 Motion Controllers TM262M25MESS8T and TM262M35MESS8T are supported now with the following stipulations:
Sercos cycle time must be set to 4 ms.
One M262 controller can control one robot.
The method IF_RobotConfiguration.SchneiderElectricRobot is not supported.
The tracking methods IF_RobotConfiguration.AddLinearTrackingSystem, IF_RobotConfiguration.AddLinearTrackingSystem2, IF_RobotConfiguration.AddLinearTrackingSystem3, and IF_RobotConfiguration.AddRotativeTrackingSystem are not supported.
For Modicon M262 Motion Controllers: If FB_Robot and/or IF_Robot report a diagnostic message and the axis is in MOIN.ET_AxisState.ErrorStop state, FB_Robot and/or IF_Robot must be disabled and MC_Reset must be executed to reset the axis.
IF_RobotConfigurationAdvanced.xShiftMoveSyncStartPosition
The start position on the connected path of a MoveSync command is shifted to the earliest possible position.
For Modicon M262 Motion Controllers with an axis configured as modulo, the property xEnable of FB_Robot does not operate as intended.
If you set xEnable to TRUE a diagnostic message is reported.
Workaround:
Disable the robot.
Modify the axis from modulo to linear.
Enable the robot. Result: A diagnostic message is reported.
Disable the robot again.
Enable the robot.