ControlMode

General

Type

EF

Offline editable

Yes

Devices supporting the parameter

Lexium LXM52 Drive,

Lexium LXM62 Drive

Traceable

Functional Description

The parameter is used to select the motor control mode.

Value

Data type

Meaning

closed-loop control / 0

DINT

The servo amplifier works in closed-loop controlled operation. An encoder is required for the closed-loop controlled operation.

open-loop control / 1

DINT

The servo amplifier works in the open-loop controlled operation. The controller works without an encoder (no feedback). Only asynchronous motors can be used in the open-loop controlled operation. The speed of rotation is not monitored.

encoderless velocity closed-loop control / 2

DINT

The servo amplifier works in the encoderless velocity control operation. The controller works without a position sensor (any kind of encoder).

This setting has no effect for the Lexium LXM52 Drive.

The parameter is only transferred to the drive by a Sercos phase up (phase 0 => phase 4). After modification of the parameter, a new Sercos phase up has to be performed.