Function: M functions or additional functions start actions during the interpolation of G code.
The interpolator decelerates to velocity 0, sends the number of the queued M function to the output wM
, and waits for the confirmation in bAcknM
before accelerating again. As opposed to the switch point, the program remains at the current position until the M function is confirmed by setting the input at the interpolator.
If SMC_PreAcknowledgeM
is executed, then the function block confirms the M function early. If the function block is executed on time, then the interpolator does not halt and the program continues as if the M instruction was not present.
An M function is implemented by the application and not defined by the system.
Syntax
M K L O
G code word |
Description |
---|---|
|
Number of the M function, M >0 Note: The numbers 65533 - 65535 are reserved for internal functions. |
|
Numeric parameter ( |
|
Numeric parameter ( |
|
References with O$var$ a variable of type |
Examples
M with parameter
The M function 10 starts. For the program execution of N90, the system waits until the confirmation is available.
N90 M10 K100.7
M with additional parameter
The M function 10 starts. The user-defined data structure g_myMParams
(data type SMC_M_PARAMETER
) is referenced with O$var$. g_myMParams
contains additional parameters. The values of K, L, and the parameters from g_myMParams
can be read at the time of the path stop of the M function. This is done by calling an instance of the function block SMC_GetMParameters
.
N150 M13 O$g_myMParams$