FC_NegativePart

 

FC_NegativePart - General Information

Overview

Type:

Function

Available as of:

V1.0.3.0

Versions:

Current version

Task

Determine the negative part of a value.

Description

The negative part is defined as follows:

oi_lrValue >= 0.0 -> 0.0

oi_lrValue < 0.0 -> ABS(i_lrValue)

Together with the function FC_PositivePart the following identity applies to all real lrValues:

lrValue = FC_PositivePart(lrValue) - FC_NegativePart(lrValue)

Interface

Input

Data type

Description

i_lrValue

LREAL

Value of the number of which the negative part is to be determined

Output

Data type

Description

q_etDiag

GD.ET_Diag

General library-independent statement on the diagnostic.

A value not equal to ET_Diag.Ok corresponds to an diagnostic message.

q_etDiagExt

ET_DiagExt

POU-specific output on the diagnostic.

q_etDiag = ET_Diag.Ok -> Status message

q_etDiag <> ET_Diag.Ok -> Diagnostic message

Return Value

Data type

Description

LREAL

Negative part of the value i_lrValue

Diagnostic Messages

q_etDiag

q_etDiagExt

Enumeration value

Description

OK

Ok

0

Ok

Ok

Enumeration name:

Ok

Enumeration value:

0

Description:

Ok

The negative part has been calculated successfully.