Using the library with other versions of software or firmware may have results other than described in the present documentation.
WARNING | |
---|---|
PacDrive 3 V4.4
PacDrive LMC Eco V1.56.15.12 or greater
PacDrive LMC Pro V1.56.15.12 or greater
PacDrive LMC Pro2 V1.56.15.12 or greater
New robot types added to ET_RobotPSeries:
P2 robots: VRKP2S0FWD00000, VRKP2S0RWD00000
Drive parameter UserDrivePeakCurren
Lexium P Robot (SH and ILM motors)
The drive parameter UserDrivePeakCurrent can be set to a value greater than 5500 mA.
The maximum value is 7500 mA.
Lexium T Robot (MH motors)
The drive parameter UserDrivePeakCurrent can be set to a value greater than 8185 mA.
The maximum value is 13000 mA.
Lexium T Robot (MH motors HD)
The drive parameter UserDrivePeakCurrent can be set to a value greater than 8325 mA.
The maximum value is 13000 mA.
Lexium T Robot (ILM motors)
The drive parameter UserDrivePeakCurrent can be set to a value greater than 5800 mA.
The maximum value is 7000 mA.
If a value greater than the previous maximum value is configured, a current limit is calculated dynamically by using the drive parameter UserCurrentLimit.