Type |
AF |
|
Devices supporting the parameter |
Lexium LXM62 Drive |
|
Device variants supporting the parameter |
Standard Plus, Advanced Plus, Application defined |
|
Traceable |
Yes |
The parameter represents the threshold velocity in Unit/s as of which the motor is switched between open-loop control mode and closed-loop control mode. Encoderless closed-loop control is only possible above this threshold velocity.
When the MinimalOperatingVelocity limit is exceeded, the motor operates in encoderless closed-loop control mode (the speed and position controller is closed). (See Encoderless Velocity Control User Function.)
When the velocity is less than the limit, the motor runs in open-loop control (the speed and position controller is not closed). (See Encoderless Velocity Control User Function.)