About the Book

Document Scope

The purpose of this document is to help you to configure your Modicon M218 Logic Controller.

NOTE: Read and understand this document and all related documents before installing, operating, or maintaining your Modicon M218 Logic Controller.

The Modicon M218 Logic Controller users should read through the entire document to understand all features.

Validity Note

This document has been updated with the release of EcoStruxureTM Machine Expert V1.1.

Related Documents

Title of Documentation

Reference Number

EcoStruxure Machine Expert Programming Guide

EIO0000002854(eng)

EIO0000002859 (chs)

Modicon M218 Logic Controller Hardware Guide

EIO0000003616 (eng)

EIO0000003617 (chs)

Modicon TM2...N Expansion Modules Programming Guide

EIO0000003784 (eng)

EIO0000003785 (chs)

Modicon TM2 Modules Configuration Programming Guide

EIO0000003432 (eng)

EIO0000003437 (chs)

Modicon TM3 Modules Configuration Programming Guide

EIO0000003119 (eng)

EIO0000003124 (chs)

Modicon M218 Logic Controller System Functions and Variables M218 PLCSystem Library Guide

EIO0000003620 (eng)

EIO0000003621 (chs)

Modicon M218 Logic Controller High Speed Counting M218 HSC Library Guide

EIO0000003618 (eng)

EIO0000003619 (chs)

Modicon M218 Logic Controller Pulse Train Output, Pulse Width Modulation M218 PTOPWM Library Guide

EIO0000003729 (eng)

EIO0000003730 (chs)

Modicon M218 Logic Controller Packaging Library M218 Packaging Library Guide

EIO0000003731 (eng)

EIO0000003732 (chs)

You can download these technical publications and other technical information from our website at https://www.schneider-electric.com/en/download

Product Related Information

Warning_Color.gifWARNING

LOSS OF CONTROL

oThe designer of any control scheme must consider the potential failure modes of control paths and, for certain critical control functions, provide a means to achieve a safe state during and after a path failure. Examples of critical control functions are emergency stop and overtravel stop, power outage and restart.

oSeparate or redundant control paths must be provided for critical control functions.

oSystem control paths may include communication links. Consideration must be given to the implications of unanticipated transmission delays or failures of the link.

oObserve all accident prevention regulations and local safety guidelines.1

oEach implementation of this equipment must be individually and thoroughly tested for proper operation before being placed into service.

Failure to follow these instructions can result in death, serious injury, or equipment damage.

1 For additional information, refer to NEMA ICS 1.1 (latest edition), "Safety Guidelines for the Application, Installation, and Maintenance of Solid State Control" and to NEMA ICS 7.1 (latest edition), "Safety Standards for Construction and Guide for Selection, Installation and Operation of Adjustable-Speed Drive Systems" or their equivalent governing your particular location.

Warning_Color.gifWARNING

UNINTENDED EQUIPMENT OPERATION

oOnly use software approved by Schneider Electric for use with this equipment.

oUpdate your application program every time you change the physical hardware configuration.

Failure to follow these instructions can result in death, serious injury, or equipment damage.