ZeroTrackStart

General

Type

EF

Devices supporting the parameter

Incremental Encoder Input

Traceable

Yes

Functional Description

Enables the zero track detection.

A rising edge of this parameter (from false / 0 -> true / 1) activates the zero track detection on the incremental encoder input. Zero track detection evaluates the level of the zero track of the incremental encoder.

Value

Data type

Meaning

false / 0

BOOLEAN

Zero track detection disabled.

true / 1

BOOLEAN

Zero track detection enabled.

NOTE: When a zero track occurs, the module immediately sets the internal increment counter to 0. In the next Sercos cycle, Position and Velocity are corrected.

This is not relevant when you are using the zero track as a reference. When you are using the zero track for a highly cyclic activity, the slight deviation in velocity can cause the position to deviate.

The Position results from the counter status.