EnableSet

General

Type

ES

Offline editable

No

Devices supporting the parameter

Lexium MC Track

Traceable

Yes

Functional description

The parameter enables or disables the track:
  • The parameter enables or disables the Lexium MC Carrier objects related to the track.

    NOTE: If more than one track has been configured, the parameter EnableSet enables or disables only the Lexium MC Carrier objects for the corresponding track.
  • The parameter sets or unsets (depending on the value 0 or 1) the parameter EnableSet of the Lexium MC Segment objects of the track.

The parameter EnableSet of the related devices is transferred via the Sercos real-time communication and becomes active on the physical devices as soon as the real- time communication is active. If the values are written in an earlier state of the Sercos communication, the values will automatically be transferred as soon as the Sercos real-time communication is active.

Value

Data type

Meaning

Disable / 0
(default)

BOOL

Disables the track.

Enable / 1

BOOL

Enables the track.