FB_RobotPSeriesParameters - InitializeRotationalAxis (Method)

Overview

Type:

Method

Available as of:

V1.0.0.0

Versions:

Current version

This chapter provides information on:

Task

Initialize a rotational axis of the robot.

Description

By calling up the method, a rotational axis is added to the robot type that is selected by the method InitializeRobot.

Interface

Input

Data type

Description

i_ifDrive

SystemConfigurationItf.IF_Drive

Drive of a rotational axis.

i_lrPeriodStart

LREAL

Position of the rotational axis where the period starts.

Further information can be found under ROB.IF_RobotConfiguration.AddAuxAx of the library Robotic.

i_lrPeriodLength

LREAL

Length of the rotational axis period.

Value range: i_lrPeriodLength ≥ 0.0

i_lrPeriodLength = 0.0 -> The auxiliary axis does not have a period. The value entered in i_lrPeriodStart is ignored.

Output

Data type

Description

q_etDiag

GD.ET_Diag

General, library-independent statement on the diagnostic.

A value not equal to ET_Diag.Ok corresponds to a diagnostic message.

q_etDiagExt

ET_DiagExt

POU-specific output for the diagnostic.

q_etDiag = ET_Diag.Ok -> status message

q_etDiag <> ET_Diag.Ok -> diagnostic message

q_sMsg

STRING[80]

Event-triggered message that gives additional information on the diagnostic state.

Diagnostic Messages

q_etDiag

q_etDiagExt

Enumeration value

Description

OK

NoRotationalAxisRequired

11

There is no rotational axis required.

OK

Ok

0

Ok

ExecutionAborted

RobotNotInitialized

6

The robot is not initialized.

InputParameterInvalid

DriveInvalid

4

The drive is invalid.

InputParameterInvalid

PeriodLengthRange

9

The period length is out of range.

DriveInvalid

Enumeration name:

DriveInvalid

Enumeration value:

4

Description:

The drive is invalid.

Issue

Cause

Solution

The configuration of the rotational axis was unsuccessful.

The interface transferred at the input i_ifDrive is invalid.

Ensure that the transferred interface is an interface of a valid drive.

The following interfaces have to be implemented by the drive object:

  • SystemConfigurationItf.IF_Mechanic

  • SystemConfigurationItf.IF_SetLimits

  • SystemConfigurationItf.IF_Motor

  • SystemConfigurationItf.IF_ControlLoop

  • SystemConfigurationItf.IF_RefActualValues

  • SystemConfigurationItf.IF_ControlMode

  • SystemConfigurationItf.IF_EncoderGear

  • SystemConfigurationItf.IF_EncoderDirection

  • SystemConfigurationItf.IF_Brake

  • SystemConfigurationItf.IF_YoffsetGenerator

NoRotationalAxisRequired

Enumeration name:

NoRotationalAxisRequired

Enumeration value:

11

Description:

There is no rotational axis required.

Configuring the rotational axis is not necessary.

Ok

Enumeration name:

Ok

Enumeration value:

0

Description:

Ok

The configuration of the rotational axis was successful.

PeriodLengthRange

Enumeration name:

PeriodLengthRange

Enumeration value:

9

Description:

The period length is out of range.

Issue

Cause

Solution

The configuration of the rotational axis was unsuccessful.

The value transferred at the input i_lrPeriodLength is outside of the valid range.

At the input i_lrPeriodLength, a value greater than or equal to 0 must be transferred.

RobotNotInitialized

Enumeration name:

RobotNotInitialized

Enumeration value:

6

Description:

The robot is not initialized.

Issue

Cause

Solution

The configuration of the rotational axis was unsuccessful.

The Lexium P Robot is not initialized.

Call the method InitializeRobot before calling the method InitializeRotationalAxis.