IF_ProductManager - SetFirstProductToBelt (Method)
|
Type: |
Method |
|
Available as of: |
V1.0.0.0 |
|
Versions: |
Current version |
Transfers the first product of a belt to another belt
The product that is closest to the end of the belt is allocated to the specified belt.
If a product changes the belt, it is automatically transferred to the next belt according to the set InTakeMode. If a product is to be allocated manually to another belt, this can be performed using this method.
|
Input |
Data type |
Description |
|---|---|---|
|
i_udiRemoveBeltId |
UDINT |
The number of the belt from which the first product is to change the belt |
|
i_udiAddBeltId |
UDINT |
The number of the belt to which the product is to be allocated |
|
i_lrLeadEdge |
LREAL |
The distance of the front edge of the product to the end of the belt on which the product is to change |
|
i_lrTrailEdge |
LREAL |
The distance of the rear edge of the product to the end of the belt on which the product is to change |
|
Output |
Data type |
Description |
|---|---|---|
|
q_etDiag |
General, library-independent statement on the diagnosis. A value unequal GD.ET_Diag.Ok equates an error message. |
|
|
q_etDiagExt |
POU-specific output on the diagnosis. q_etDiag = GD.ET_Diag.Ok -> status message q_etDiag <> GD.ET_Diag.Ok -> error message |
|
|
q_ifProduct |
The interface with the product that has changed the belt |
|
q_etDiag |
q_etDiagExt |
Enumeration value |
Description |
|---|---|---|---|
|
OK |
0 |
Ok |
|
|
ExecutionAborted |
71 |
No product could be found. |
|
|
InputParameterInvalid |
70 |
AddBeltId is outside the valid range. |
|
|
InputParameterInvalid |
69 |
RemoveBeltId is outside the valid range. |
|
|
UnexpectedProgramBehavior |
38 |
No valid logger POU has been transferred. |
|
Enumeration name: |
AddBeltIdRange |
|
Enumeration value: |
70 |
|
Description: |
AddBeltId is outside the valid range. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
- |
An invalid value has been transferred at the input i_udiAddBeltId. |
At the i_udiAddBeltId input, the number of the belt has to be specified to which the product is to change. The number must be between one and the number of parameterized belts. |
|
Enumeration name: |
LoggerInvalid |
|
Enumeration value: |
38 |
|
Description: |
No valid logger POU has been transferred. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
- |
An error occurred in the internal execution. |
Please inform the support team about this error. |
|
Enumeration name: |
NoProductExisting |
|
Enumeration value: |
71 |
|
Description: |
No product could be found. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
- |
The product does not exist. |
It must be made sure that a product is located on the belt specified at the i_udiRemoveBeltId input. |
|
Enumeration name: |
Ok |
|
Enumeration value: |
0 |
|
Description: |
Ok |
The product has successfully been allocated to another belt.
|
Enumeration name: |
RemoveBeltIdRange |
|
Enumeration value: |
69 |
|
Description: |
RemoveBeltId is outside the valid range. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
- |
An invalid value has been transferred at the input i_udiRemoveBeltId. |
At the i_udiRemoveBeltId input, the number of the belt has to be specified from which the product is to be removed. The number must be between one and the number of parameterized belts. |