State

General

Type

AD

Devices supporting the parameter

Incremental Encoder Input

Traceable

Yes

Functional Description

Displays the availability and the validity of the encoder position data.

Value

Data type

Meaning

not ready / 0

DINT

The encoder or encoder processing is not ready.

Initialization / 1

DINT

Encoder processing is initialized.

not synchronous / 2

DINT

Encoder processing does not run synchronously with real-time processing (Sercos bus is not in phase 4). The velocity and position values of the encoder are not exact and therefore cannot be used.

ready / 3

DINT

The velocity and position values of the encoder are valid.

NOTE: The Incremental Encoder Input object can only control the TM5 module if the parameter OutputsActiveSet of the parent bus coupler is set to on / 1. The bus coupler then begins to transfer the output values to the module.

This is needed to control the error detection and the ZeroTrack detection.

The states of the Incremental Encoder Input object are processed in the following order:

1.not ready / 0

2.Initialization / 1

3.not synchronous / 2

4.ready / 3

NOTE: In TM5 encoder inputs, the not synchronous / 2 state is processed before the Initialization / 1 state because the module can be initialized not before the Incremental Encoder Input object can access the cyclic output registers of the module.