Information About Lubrication

Overview

Lubricant is consumed continuously during operation of the actuator. The actuator must be lubricated at regular intervals. Incorrect lubricants may damage the actuator.

Insufficient lubrication or incorrect lubricants increase wear and reduce the service life.

NOTICE

INOPERABLE AXIS

Only use the specified type and amount of lubricant.

Failure to follow these instructions can result in equipment damage.

For lubricating the actuator, only use Lubcon TURMOGREASE LC 802 EP or alternative grease with label K HC P 2/3 N-30 according to DIN 51825.

Note that a small amount of lubricants may leak. For further information, refer to Emissions.

NOTE: Always wear protective clothing when working on the system. Repeated and prolonged exposure to the product can cause skin irritation, or sickness if ingested.

Caution_Color.gifCAUTION

EYE OR SKIN CONTACT WITH, OR INGESTION OF, LUBRICANTS

oIn the event of contact with the eyes or the skin, wash the affected areas with plenty of water; if irritation persists, consult a doctor.

oIn the event of swallowing, do not provoke vomiting or administer any products orally; consult a doctor as soon as possible.

Failure to follow these instructions can result in injury or equipment damage.