Every 150 hours of operation
or
weekly
|
-
Verify the robot by visual inspection for any damage or missing parts, especially for moving parts and parts at risk for collisions such as grippers, upper arms, lower arms, springs, telescopic axis, or parallel plates.
-
Replace the arms if these are bent or dented.
-
Clean the robot mechanics.
|
Every 300 hours of operation
or
every two weeks
|
-
Verify the slide films, ball sockets, universal joints, and rolls for wear and replace them if necessary.
-
Only for an optionally mounted VRKPXYYYYY00038, VRKPXYYYYY00039, VRKPXYYYYY00041, VRKPXYYYYY00045, VRKPXYYYYY00046, VRKPXYYYYY00049, VRKPXYYYYY00050, VRKPXYYYYY00052, or VRKPXYYYYY00053:
Verify the cables for wear and replace them if these are damaged or worn out
|
Every 1,000 hours of operation
or
every three months
|
-
Verify all moving parts for bolted connections.
-
Verify the output shaft sealing of gearboxes for deposits of dirt and clean.
-
Verify the sealing gaskets at maintenance covers, media covers and motor covers by visual inspection for any damage and replace them if necessary.
|
Every 2,000 hours of operation
|
-
Replace the springs and spring rolls of the lower arms.
-
Replace the ball sockets.
-
Replace the slide films of the telescopic axis.
-
Verify the universal joints on the telescopic axis and replace them if these are appreciably worn.
|
Every 5,000 hours of operation
|
|
Annually
|
|
Every 20,000 hours of operation
|
-
Replace the main gearboxes and motors.
-
Replace the four-axis parallel plate (with rotational axis bearing).
-
Only for VRKP2•••WD / VRKP4•••WD / VRKP4•••NO / VRKP4•••CW / VRKP4•••WF / VRKP5•••WF / VRKP6•••WF robot:
Verify the fans for operation and replace them if necessary.
-
When using an optionally mounted VRKPXYYYYY00038, VRKPXYYYYY00039, VRKPXYYYYY00041, VRKPXYYYYY00045, VRKPXYYYYY00046, VRKPXYYYYY00049, VRKPXYYYYY00050, VRKPXYYYYY00052, or VRKPXYYYYY00053:
Replace the module.
|
Every 40,000 hours of operation
|
|
Every 1,000 emergency stop situations
|
|
Each removal of the covers
|
|