Procedure |
Parameter |
Unit |
Value |
---|---|---|---|
Operation |
Class 3K3, 3Z12, 3Z2, 3B2, 3C1, 3M6 (according to IEC/EN 60721-3-3)(1) |
||
Ambient temperature |
°C (°F) |
+5…+55 (+41…+131)(2) |
|
Condensation |
– |
prohibited |
|
Formation of ice |
– |
prohibited |
|
Relative humidity |
% |
5…85 |
|
Transport |
Set of class combinations IE21 (according to IEC/EN 60721-3-2)(3) |
||
Ambient temperature |
°C (°F) |
-25…+60 (-13…+140) |
|
Condensation |
– |
prohibited |
|
Precipitation |
– |
prohibited |
|
Formation of ice |
– |
prohibited |
|
Other liquid |
– |
prohibited |
|
Wetness |
– |
prohibited |
|
Relative humidity |
% |
< 75 |
|
Long-term storage in transport packaging |
Class 1K3 (according to IEC/EN 60721-3-1) |
||
Ambient temperature |
°C (°F) |
+5…+30 (+41…+86)(4) |
|
Condensation |
– |
prohibited |
|
Precipitation |
– |
prohibited |
|
Formation of ice |
– |
prohibited |
|
Other liquid |
– |
prohibited |
|
Wetness |
– |
prohibited |
|
Relative humidity |
% |
5…95(5) |
|
Maximum storage period |
years |
2 |
|
(1) All parameters conform to the specified class except for the ambient temperature which is limited by other components of the system. (2) Power reduction with motors at ambient temperatures exceeding +40 °C (104 °F). For more information, contact your local Schneider Electric service representative. (3) All parameters conform to the specified class except for the relative humidity which is limited by other components of the system. (4) Higher temperatures can cause damage to the superficial structure. Lower temperatures increase the stiffness and reduce the service life of the toothed belt. (5) Storing the toothed belt at a relative humidity of maximum 50% helps to avoid a reduced service life of the toothed belt. |
Ambient conditions apply with motor and gearbox. For further information, refer to the corresponding motor or gearbox manual.
For further information about storage conditions, refer to Transport and Storage.
Information About Increased Corrosion Resistance
Increased corrosion resistance does not imply corrosion resistance under any ambient condition. For further information, refer to Incompatible Environments.
NOTE: Coated materials loose their increased corrosion resistance if the coating is damaged or worn.
Component |
Without an increased corrosion resistance |
With an increased corrosion resistance |
|
---|---|---|---|
Axis body |
Aluminum, anodized |
||
Ball bearing seals |
Nitrile Butadiene Rubber (NBR) |
||
Carriage |
Aluminum, anodized |
||
Circlips |
Steel, galvanized |
||
Clamping claws |
Aluminum, anodized |
||
Clamping hub |
Aluminum, not anodized |
||
Contact plate |
Stainless steel |
||
Cover end blocks |
Polyoxymethylene (POM) |
||
Cover strip |
Steel, not stainless, Teflon-coated |
||
Cover strip clamps |
Housings |
Polyphenylene sulfide |
|
Clamping plates |
Stainless steel |
||
Elastomer spider |
Polyurethane (PUR) |
||
End blocks |
Aluminum, die-cast, not anodized |
||
Expanding hub |
Aluminum, not anodized; cone stainless steel |
||
Gearbox and motor adaptations |
Aluminum, not anodized |
||
Grease nipples |
Stainless steel |
||
Locating dowels |
Stainless steel |
||
Recirculating ball bearing guide |
Guide rail |
Steel |
Armoloy-coated |
Guide carriages |
Steel |
||
Roller guide |
Guide rods |
Steel |
Stainless steel |
Rollers |
Steel |
Stainless steel |
|
Rubber buffers |
Styrene Butadiene Rubber (SBR) |
||
Screws |
Steel, galvanized |
||
Sensors |
Brass, nickel-plated |
||
Sensor cables |
Polyurethane (PUR) |
||
Sensor holders |
Polyoxymethylene (POM) |
||
Shaft extension |
Aluminum, not anodized; cone stainless steel |
||
Slot nuts |
Steel, galvanized |
||
Strip deflectors |
Housings |
Aluminum, anodized |
|
Deflection units |
Polyamide (PA) |
||
Brushes |
Polyamide (PA) |
||
Toothed belt |
Belt |
Polyurethane (PUR) |
|
Fibres |
Polyamide (PA) |
||
Tension members |
Steel, galvanized |
||
Toothed belt, antistatic |
Belt |
Polyurethane (PUR) |
|
Fibres |
Polyamide (PA), conductive |
||
Tension members |
Steel, galvanized |
||
Toothed belt pulleys |
Toothed belt pulleys |
Aluminum |
|
Flanged wheels |
Steel, galvanized |
||
Ball bearings |
Steel |
Stainless steel |
|
Toothed belt tensioners |
Stainless steel |