4 AI; 4 AI;–; 4 AO; 4 AO
Compact I/O module with 2x4 analog inputs and 2x4 analog outputs, 0...20 mA / 4...20 mA; 12 bits
The module consists of the following five inseparable submodules:
One submodule (slot 1 + slot 2) with each four analog current inputs
One dummy module (slot 3)
One submodule (slot 4 + slot 5) with each four analog current outputs
Register |
Meaning |
Default |
Data type |
---|---|---|---|
Submodule 1 |
|||
0+0 |
Analog input 01 |
0...20 mA |
INT |
0+2 |
Analog input 02 |
0...20 mA |
INT |
0+4 |
Analog input 03 |
0...20 mA |
INT |
0+6 |
Analog input 04 |
0...20 mA |
INT |
0+18 |
0 |
USINT |
|
0+30 |
– |
USINT |
|
Submodule 2 |
|||
32+0 |
Analog input 01 |
0...20 mA |
INT |
32+2 |
Analog input 02 |
0...20 mA |
INT |
32+4 |
Analog input 03 |
0...20 mA |
INT |
32+6 |
Analog input 04 |
0...20 mA |
INT |
32+18 |
0 |
USINT |
|
32+30 |
– |
USINT |
|
Submodule 3 |
|||
– |
– |
– |
– |
Submodule 4 |
|||
96+0 |
Output 01 |
0...20 mA |
INT |
96+2 |
Output 02 |
0...20 mA |
INT |
96+4 |
Output 03 |
0...20 mA |
INT |
96+6 |
Output 04 |
0...20 mA |
INT |
96+18 |
0 |
USINT |
|
Submodule 5 |
|||
128+0 |
Output 01 |
0...20 mA |
INT |
128+2 |
Output 02 |
0...20 mA |
INT |
128+4 |
Output 03 |
0...20 mA |
INT |
128+6 |
Output 04 |
0...20 mA |
INT |
128+18 |
0 |
USINT |
In order to parameterize a module per PLC Configuration in the device editor, proceed as follows:
Step |
Action |
---|---|
1 |
Append module in the TM5NS31). beneath a Sercos III bus interface ( |
2 |
Afterwards double-click the module in the .Result: The device editor is opened and the tabs , , and are displayed. |
The input and output channels of the module are mapped to project variables that are used by the application.
Channel |
Meaning |
Default value |
Data type |
---|---|---|---|
Analog inputs (slot 1+2) |
SL1 analog input 01 SL1 analog input 02 SL1 analog input 03 SL1 analog input 04 SL2 analog input 01 SL2 analog input 02 SL2 analog input 03 SL2 analog input 04 |
– |
INT |
Dummy module (slot 3) |
– |
– |
– |
Analog outputs (slot 4+5) |
SL4 analog output 01 SL4 analog output 02 SL4 analog output 03 SL4 analog output 04 SL5 analog output 01 SL5 analog output 02 SL5 analog output 03 SL5 analog output 04 |
– |
INT |
Status of the analog inputs slot 1+2 |
Status of the analog inputs SL1 Status of the analog inputs SL2 |
– |
BYTE |
The check box
is used for switching between the numeric and the symbolic value.
Name |
Meaning |
Numeric/symbolic value |
Default value |
Data type |
---|---|---|---|---|
SL 1_Channel-Type01 |
Slot 1 analog input |
1/0...20 mA 17/4...20 mA |
1/0...20 mA |
BYTE |
SL 1_Channel-Type02 |
Slot 1 analog input |
2/0...20 mA 34/4...20 mA |
2/0...20 mA |
BYTE |
SL 1_Channel-Type03 |
Slot 1 analog input |
4/0...20 mA 68/4...20 mA |
4/0...20 mA |
BYTE |
SL 1_Channel-Type04 |
Slot 1 analog input |
8/0...20 mA 136/4...20 mA |
8/0...20 mA |
BYTE |
SL 2_Channel-Type01 |
Slot 2 analog input |
1/0...20 mA 17/4...20 mA |
1/0...20 mA |
BYTE |
SL 2_Channel-Type02 |
Slot 2 analog input |
2/0...20 mA 34/4...20 mA |
2/0...20 mA |
BYTE |
SL 2_Channel-Type03 |
Slot 2 analog input |
4/0...20 mA 68/4...20 mA |
4/0...20 mA |
BYTE |
SL 2_Channel-Type04 |
Slot 2 analog input |
8/0...20 mA 136/4...20 mA |
8/0...20 mA |
BYTE |
SL 3 dummy module |
– |
– |
– |
– |
SL 4_Channel-Type01 |
Slot 4 analog output |
1/0...20 mA 17/4...20 mA |
1/0...20 mA |
BYTE |
SL 4_Channel-Type02 |
Slot 4 analog output |
2/0...20 mA 34/4...20 mA |
2/0...20 mA |
BYTE |
SL 4_Channel-Type03 |
Slot 4 analog output |
4/0...20 mA 68/4...20 mA |
4/0...20 mA |
BYTE |
SL 4_Channel-Type04 |
Slot 4 analog output |
8/0...20 mA 136/4...20 mA |
8/0...20 mA |
BYTE |
SL 5_Channel-Type01 |
Slot 5 analog output |
1/0...20 mA 17/4...20 mA |
1/0...20 mA |
BYTE |
SL 5_Channel-Type02 |
Slot 5 analog output |
2/0...20 mA 34/4...20 mA |
2/0...20 mA |
BYTE |
SL 5_Channel-Type03 |
Slot 5 analog output |
4/0...20 mA 68/4...20 mA |
4/0...20 mA |
BYTE |
SL 5_Channel-Type04 |
Slot 5 analog output |
8/0...20 mA 136/4...20 mA |
8/0...20 mA |
BYTE |
For further information, see the TM5 compact I/O modules hardware manual.