Type |
EF |
Offline editable |
Yes |
Devices supporting the parameter |
Lexium LXM52 Drive, Lexium LXM52 Linear Drive, Lexium LXM62 Drive, Lexium LXM62 Linear Drive, Lexium ILM62 Drive Module |
Traceable |
Yes |
The parameter MotorIdentification was introduced to support different motor configurations for a drive.
NOTICE | |
---|---|
Value |
Data type |
Meaning |
---|---|---|
Motor with type plate / 0 |
DINT |
Normal operation. The motor nameplate is saved in the encoder-EEPROM of the motor. |
motorless / 1 |
DINT |
No motor is connected to the servo amplifier. Servo amplifier in an inactive status. No motion tasks can be performed. |
Motor without type plate / 2 |
DINT |
The motor nameplate is saved in the servo amplifier. Not supported in V1.31.10.0. Drive reports non-supported mode (service channel diagnostic message). |
8997 MotorIdentification invalid
is triggered during the Sercos phase up.