General Information

Library Overview

The library IoLinkHandling provides the functionality to configure the IO-Link master and the IO-Link devices from within the application.

Therefore, dedicated function blocks to read and write device parameters, configure IO-Link master user parameters, and react on events generated by the IO-Link master and devices are implemented.

Characteristics of the Library

The table indicates the characteristics of the library:

Characteristic

Value

Library title

IoLinkHandling

Company

Schneider Electric

Category

Generic

Component

Core Libraries

Default namespace

SE_IoLink

Language model attribute

Qualified-access-only

Forward compatible library

Yes FCL

NOTE: For this library, qualified-access-only is set. The POUs, data structures, enumerations, and constants must be accessed using the namespace of the library. The default namespace of the library is SE_IoLink.

Controller Platforms

The IoLinkHandling library is supported by the following controller platforms:

  • Modicon M262 Logic/Motion Controllers

  • PacDrive LMC controllers

Function / function block

Protocol

M262

LMC

FB_ReadDeviceParameter

Sercos

ok

ok

EtherNet/IP

ok

not supported by platform

FB_WriteDeviceParameter

Sercos

ok

ok

EtherNet/IP

ok

not supported by platform

FB_WriteMasterUserParameter

Sercos

ok

ok

EtherNet/IP

ok

not supported by platform

FB_RegisterEvent

-

ok

ok

FB_EventLogger

-

ok

ok

FC_GetIoLinkMasterConnectionStatus

-

ok

ok

General Considerations

NOTE: Schneider Electric adheres to industry best practices in the development and implementation of control systems. This includes a "Defense-in-Depth" approach to secure an Industrial Control System. This approach places the controllers behind one or more firewalls to restrict access to authorized personnel and protocols only.
 WARNING
UNAUTHENTICATED ACCESS AND SUBSEQUENT UNAUTHORIZED MACHINE OPERATION
  • Evaluate whether your environment or your machines are connected to your critical infrastructure and, if so, take appropriate steps in terms of prevention, based on Defense-in-Depth, before connecting the automation system to any network.
  • Limit the number of devices connected to a network to the minimum necessary.
  • Isolate your industrial network from other networks inside your company.
  • Protect any network against unintended access by using firewalls, VPN, or other, proven security measures.
  • Monitor activities within your systems.
  • Prevent subject devices from direct access or direct link by unauthorized parties or unauthenticated actions.
  • Prepare a recovery plan including backup of your system and process information.
Failure to follow these instructions can result in death, serious injury, or equipment damage.

For more information on organizational measures and rules covering access to infrastructures, refer to ISO/IEC 27000 series, Common Criteria for Information Technology Security Evaluation, ISO/IEC 15408, IEC 62351, ISA/IEC 62443, NIST Cybersecurity Framework, Information Security Forum - Standard of Good Practice for Information Security and refer to Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment.