Periodically verify and replace the ball sockets in accordance with the maintenance schedule.
Clean the ball sockets at regular intervals.
Step |
Action |
---|---|
1 |
Place a level object, for example, a hex key (1), on the outside of the respective lower arm head of the ready-to-operate robot.
NOTE: The ball sockets can be verified in the working space when the robot is installed and in random position.
![]() |
2 |
If the level object is not laying plane on the lower arm head and is in contact with the ball pin, replace the ball socket. |