Input |
Data type |
Description |
|---|---|---|
|
i_udiToolId |
UDINT |
ID of the tool. |
|
Output |
Data type |
Description |
|---|---|---|
|
q_etDiag |
General library-independent statement on the diagnostic. A value not equal to GD.ET_Diag.Ok corresponds to a diagnostic message. |
|
|
q_etDiagExt |
POU-specific output on the diagnostic. q_etDiag = ET_Diag.Ok -> Status message q_etDiag <> ET_Diag.Ok -> Diagnostic message |
|
|
q_sMsg |
STRING[80] |
Event-triggered message that gives additional information on the diagnostic state. |
|
q_stPositionOffset |
Position offset of the tool. |
|
|
q_stOrientationOffset |
Orientation offset of the tool. |
|
|
q_etOrientationConvention |
Orientation convention of the tool. |
|
q_etDiag |
q_etDiagExt |
Enumeration value |
Description |
|---|---|---|---|
|
OK |
OK |
0 |
Ok |
|
InputParameterInvalid |
ToolIdInvalid |
259 |
The tool ID is invalid. |
|
InputParameterInvalid |
ToolNotConfigured |
260 |
The selected tool is not configured. |
|
Enumeration name: |
ToolIdInvalid |
|
Enumeration value: |
259 |
|
Description: |
The tool ID is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The tool data was not read. |
The value provided at the input i_udiToolId is invalid. |
Ensure that a valid value is transferred at the input i_udiToolId. Valid values are >0 |
|
Enumeration name: |
ToolNotConfigured |
|
Enumeration value: |
260 |
|
Description: |
The selected tool is not configured. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The tool data was not read. |
The tool selected with the input i_udiToolId is not configured. |
Ensure that the tool with the tool ID was configured successfully. |