This function block reads the error code of the most recent detected error of error class 0.
|
Input |
Data type |
Description |
|---|---|---|
|
Enable |
BOOL |
Value range: FALSE, TRUE. Default value: FALSE. The input Enable starts or terminates execution of a function block.
|
|
Output |
Data type |
Description |
|---|---|---|
|
Valid |
BOOL |
Value range: FALSE, TRUE. Default value: FALSE.
|
|
Busy |
BOOL |
Value range: FALSE, TRUE. Default value: FALSE.
|
|
Error |
BOOL |
Value range: FALSE, TRUE. Default value: FALSE.
|
|
ErrorID |
WORD |
Returns the value of a diagnostic code. Refer to Library Diagnostic Codes. If the value is 0 and if the output Error of this function block is set to TRUE, then the diagnostic code can be read with the output AxisErrorID of the function block MC_ReadAxisError. |
|
WarningID |
WORD |
Default value: 0 Error code of the most recent detected error of error class 0. Refer to the drive documentation for a description of the error codes and classes. |