MC_ReadActualPosition

 

MC_ReadActualPosition - General Information

Overview

Type:

Function Block

Available as of:

1.0.5.0

Versions:

current version

Task

The position of the axis is to be read out.

Description

The RefPosition parameter of the axis is returned.

Interface

Input

Data type

Description

Axis

SystemConfigurationItf.IF_Drive

The axis the position of which is to be read out

Enable

BOOL

TRUE: The position is read out.

Output

Data type

Description

Valid

BOOL

TRUE if the function block has a valid output

Busy

BOOL

The function block is not finished and new outputs are still pending.

Error

BOOL

Signalizes a detected error within the function block

ErrorId

DWORD

Error identification

Position

LREAL

New position

q_etDiag

GD.ET_Diag

General, library-independent statement on the diagnostic.

A value unequal to GD.ET_Diag.Ok corresponds to a diagnostic message.

q_etDiagExt

ET_DiagExt

POU-specific output on the diagnostic.

q_etDiag = GD.ET_Diag.Ok -> status message

q_etDiag <> GD.ET_Diag.Ok -> diagnostic message

q_sMsg

STRING[80]

Event-triggered message which gives more detailed information on the diagnostic state.

Diagnostic Messages

q_etDiag

q_etDiagExt

Enumeration value

Description

OK

Ok

0

Ok

OK

Valid

2

The output values are valid.

InputParameterInvalid

AxisInvalid

25

The connected drive is not supported.

InputParameterInvalid

DriveInvalid

26

The connected drive is invalid.

InputParameterInvalid

DriveNotInitialised

27

The connected drive is not initialized.

AxisInvalid

Enumeration name:

AxisInvalid

Enumeration value:

25

Description:

The connected drive is not supported.

Issue

Cause

Solution

-

No drive has been applied at the input Axis.

A valid drive must be transferred to the input Axis.

DriveInvalid

Enumeration name:

DriveInvalid

Enumeration value:

26

Description:

The connected drive is invalid.

Issue

Cause

Solution

-

The drive connected at the input Axis does not support all required functionalities.

The drive must support the SystemConfigurationItf.IF_RefActualValuesPosition interface.

DriveNotInitialised

Enumeration name:

DriveNotInitialised

Enumeration value:

27

Description:

The connected drive is not initialized.

Issue

Cause

Solution

-

The function FC_DriveInit was not activated for the drive at the input Axis.

Before using the POU, the drive must be initialized using the function FC_DriveInit.

Ok

Enumeration name:

Ok

Enumeration value:

0

Description:

Ok

The POU is waiting for jobs.

Valid

Enumeration name:

Valid

Enumeration value:

2

Description:

The output values are valid.

The position of the axis is output.