Type |
AD |
Devices supporting the parameter |
Encoder network (Synchronization encoder output) |
Traceable |
Yes |
The parameter indicates the status of the Synchronization encoder output.
Value |
Data type |
Meaning |
---|---|---|
disabled / 0 |
DINT |
The Synchronization encoder output is disabled. |
initialization / 1 |
The Synchronization encoder output is being initialized. |
|
waiting for sync / 2 |
DINT |
The system is waiting for the Synchronization master to synchronize the entire encoder network (SyncMaster.State > 3). |
synchronized / 3 |
DINT |
The system is waiting for the encoder network to be error-free and for the Synchronization master to enable the Synchronization encoder output. Then, the configuration (DataCycleTime and DataDelay) are distributed to all Synchronization encoder inputs and the state is switched to "active / 5". |
waiting for data / 4 |
DINT |
- reserved - |
active / 5 |
DINT |
Communication is established with all Synchronization slaves and the encoder data are distributed correctly. |
error / 6 |
DINT |
An unrecoverable error occurred while distributing encoder data. Encoder data are no longer being sent. Diagnostic messages:
|