Software configuration and hardware description can be found in the following manuals:
PacDrive LMC Eco Device Objects and Parameters
PacDrive LMC Eco Motion Controller - Hardware Guide
The Schneider Electric PacDrive LMC Eco is a controller with various powerful features. It can control a wide range of applications. The PacDrive LMC Eco combines both logic controller and motion functions.
PacDrive LMC Eco controllers synchronize, coordinate, and create the motion functions of a machine for a maximum of:
0 Sercos servo drives for the controller PacDrive LMC100C
4 Sercos servo drives for the controller PacDrive LMC101C
6 Sercos servo drives for the controller PacDrive LMC106C
8 Sercos servo drives for the controller PacDrive LMC201C
12 Sercos servo drives for the controller PacDrive LMC212C
16 Sercos servo drives for the controller PacDrive LMC216C
The EcoStruxure Machine Expert software compatible with the controller provides the following IEC 61131-3 programming languages:
IL: Instruction List
ST: Structured Text
FBD: Function Block Diagram
SFC: Sequential Function Chart
LD: Ladder Diagram
EcoStruxure Machine Expert software can also be used to program the controller using CFC (Continuous Function Chart) language.
The PacDrive LMC Eco supports the following fieldbuses:
Integrated automation bus Sercos (master)
Integrated additional fieldbus CAN (master / slave)
Optional slot for additional fieldbus
The PacDrive LMC Eco supports the following I/O types:
Master encoder input
Embedded I/Os:
Digital I/Os
Advanced digital inputs (touch probe and interrupt inputs)
Distributed I/O modules on Sercos automation bus (TM5 modules)