The
dialog box provides two different tree views on the left-hand side:tree view
tree view
The
tree view lists the variables that are traced and provides access to the variable settings.The view that is displayed on the right-hand side of the
dialog box depends on the element that is selected in the tree view:
If... |
Then ... |
---|---|
A trace name is selected |
The view is displayed on the right-hand side. |
A trace variable is selected |
The view is displayed on the right-hand side. |
The contextual menu of the
tree view provides the following commands:
Command |
Description |
---|---|
|
Opens the view on the right-hand side. To add a new variable, click the browse button ( ), and select a variable for tracing. |
|
Right-click a variable and execute the command to list the diagrams that do not include the selected variable. Select a diagram to display the selected variable in this diagram.This command is deactivated if the selected variable is already assigned to all diagrams. |
|
The variables are by default enabled. Deactivated variables are displayed as disabled. They are not displayed or recorded. |
The
tree view lists the diagrams that are displayed in the trace editor and provides access to the display mode.The view that is displayed on the right-hand side of the
dialog box depends on the element that is selected in tree view:
If... |
Then ... |
---|---|
The node is selected. |
The view is displayed on the right-hand side. It allows you to specify the time axis display. |
A diagram name is selected |
The settings for the coordinate system of the diagram and a preview are displayed. |
The node is selected. |
The view is displayed on the right-hand side. It allows you to specify the axis display. |
A trace variable is selected below the node. |
The view on the right-hand side that allows you to configure the trace variables. |
The contextual menu of the
tree view provides the following commands:
Command |
Description |
---|---|
|
Adds a new diagram and displays it in the tree view. |
|
Adds a new trace variable and opens the view on the right-hand side. Select a variable in the input field to trace the value graph. Specify the display. The variable is assigned to the selected diagram. |
|
Right-click a diagram and execute the command to list the trace variables where the selected diagram is not displayed. Select a variable to display it in the selected diagram.This command is not available if all trace variables are already displayed in the selected diagram. |