Mechanical and Electrical Data for the Double Drives

Technical Data for the Double Drives

Designation

Parameter

Value

Product configuration

Item name

LXM62DU60D

LXM62DU60F

LXM62DD15D

LXM62DD15F

LXM62DD27D

LXM62DD27F

Power supply

Control voltage (without holding brakes)

Maximum current consumption

24 Vdc (-20...+25%)

1.3 A

1.3 A

1.3 A

Control voltage / control current (with holding brakes)

Maximum current consumption

24 Vdc (0...+6%)

4.1 A

4.1 A

4.1 A

DC bus voltage

250...700 Vdc

DC bus continuous current

3.6 A

9.2 A

16.4 A

DC bus peak current

11.0 A

27.4 A

49.4 A

DC bus capacitance

110 µF

Overvoltage

900 Vdc

Motor connection

Rated current (4 kHz)

  • at 40 °C (104 °F)

2.0 Aeff

5.0 Aeff

9.0 Aeff

  • at 55 °C (140 °F)

1.4 Aeff

3.5 Aeff

6.3 Aeff

Peak current 10 s (4 kHz) at 55 °C (114 °F)

6.0 Aeff

15.0 Aeff

27.0 Aeff

Continuous output power per axis (4 kHz, 400 V mains voltage)

  • at 40 °C (104 °F)

0.95 kW

2.4 kW

4.3 kW

Output voltage range

3 Vac~ 0...480 Vac

Output frequency range

0...599 Hz

Motor connection

Rated current (8 kHz)

  • at 40 °C (104 °F)

2.0 Aeff

5.0 Aeff

7.0 Aeff

  • at 55 °C (140 °F)

1.4 Aeff

3.5 Aeff

5.0 Aeff

Peak current 10 s (8 kHz) at 55 °C (140 °F)

6.0 Aeff

15.0 Aeff

27.0 Aeff

Continuous output power per axis (8 kHz, 400 V mains voltage)

  • at 40 °C (104 °F)

0.95 kW

2.4 kW

3.4 kW

Output voltage range

3 Vac~ 0...480 Vac

Output frequency range

0...599 Hz

Motor connection

Rated current (16 kHz)

  • at 40 °C (104 °F)

1.2 Aeff

3.5 Aeff

4.0 Aeff

  • at 55 °C (140 °F)

0.8 Aeff

2.6 Aeff

2.9 Aeff

Peak current 10 s (16 kHz) at 55 °C (140 °F)

6.0 Aeff

15.0 Aeff

27.0 Aeff

Continuous output power per axis (16 kHz, 400 V mains voltage)

  • at 40 °C (104 °F)

0.6 kW

1.7 kW

2.0 kW

Output voltage range

3 Vac~ 0...480 Vac

Output frequency range

0...599 Hz

Motor connection

Maximum length of the motor cable

75 m (246.06 ft)

Power loss

Electronics power supply (8 kHz)

22 W

Power stage (8 kHz)

8.5 W/A (per axis)

Interface

Sercos

Integrated

Encoder interface CN7/CN9

Power supply

10 Vdc (-10...+10%), maximum 150 mA, short-circuit protection

Differential analog input (sine and cosine signal)

Input voltage: 0.8...1.1 VPP

Offset: 2.5 Vdc (-10...+10%)

Terminating resistor: 130 Ω

SinCos periods per second

  • CN7:

    • 100 kHz (Variants C, D, G)

    • 20 kHz (Variants E, F)

  • CN9:

    • 100 kHz (Variants D, G)

    • 20 kHz (Variants F)

Cutoff frequency: Maximum 100.000 SinCos periods / second (maximum 100 kHz)

Digital inputs/ outputs

DIO supply

Voltage UDIO: 24 Vdc (-20...+25%)

Maximum current consumption: 2.2 A

Digital inputs

A_DI3, A_DI4

B_DI1, B_DI4

Inputs with switching level type 1 according to EN 61131-2

Low level: -3...5 Vdc

High level: 15...30 Vdc

Filter time constant normal inputs: 1 ms/5 ms (configurable)

Digital inputs or Touchprobe inputs

A_DI1, A_DI2

B_DI1, B_DI2

Inputs with switching level type 1 according to EN 61131-2

Low level: -3...5 Vdc

High level: 15...30 Vdc

Filter time constant normal inputs: 1 ms/5 ms (configurable)

Filter time constant for Touchprobe inputs: 100 µs

Digital inputs or digital outputs A_DI5, A_DI6

B_DI5, B_DI6

Inputs/outputs (bidirectional) with switching level type 1 according to EN 61131-2

Inputs:

Low level: -3...5 Vdc

High level: 15...30 Vdc

Filter time constant normal inputs: 1 ms/5 ms (configurable)

Outputs:

High level: (UDIO - 3 V) < Uout < UDIO

Maximum output current per output: 500 mA resistive

Inverter Enable

Maximum current consumption

30 mA

Inputs

Number: 2

STO active: -3 V ≤ UIE ≤ 5 V

Power stage active: 18 V ≤ UIE ≤ 30 V

Maximum downtime 500 µs at UIE > 20 V and dynamic activation

Maximum switching frequency of input signal: maximum 1 Hz

Maximum potential difference between IE- and PE

15 V

Ventilation

-

Internal fan

Radio interference level

-

C3 (C2 with additional filter measures)

Protective class

Class

I (IEC 61800-5-1)

Overvoltage category

-

III (IEC 61800-5-1)

Pollution degree

-

2 (IEC 61800-5-1)

Motor brake

Output voltage

Control voltage minus 0.8 Vdc

Output current

1.2 A (maximum)

Inductance

1.0 H (maximum)

Energy inductive load

1.2 J (maximum)

Overload protection

Yes

Short-circuit protection

Yes

Motor temperature sensor

-

Maximum voltage: 5 V

Maximum current: 2.5 mA

Weight

Weight

(without packaging)

3 kg (6.6 lbs)

Weight

(with packaging)

3.91 kg (8.62 lbs)

NOTE:
  • Lexium 62 Double Drive includes the variant D: LXM62DU60D, LXM62DD15D, LXM62DD27D

  • Lexium 62 Double Drive embedded safety includes the variant F: LXM62DU60F, LXM62DD15F, LXM62DD27F

Dimensions - Double Drives