As you have created your project based on the Safety Logic Controller control center.
example, it provides a prepared visualization example of a virtualThe visualization page enables you to:
Log on to the SLC and modify its password.
Visualize the status of the SLC and the connected safety-related I/O modules.
Some of this information can also be displayed in the dialog which you can open from the control dialog in Machine Expert - Safety.
Execute the
command.Execute memory key-related commands, such as formatting or copying the memory key, or confirming the memory key replacement (instead of acknowledging the replacement directly at the SLC device).
Execute configuration-related commands regarding the connected safety-related modules (confirm firmware update or module replacement, system scan).
Enable and disable Setup mode (TM5CSLC300FS and TM5CSLC400FS only). If Setup mode is enabled, module replacements, memory key replacements and firmware updates do not need to be confirmed (refer to Selection Switch SETUP MODE of TM5CSLC300FS and TM5CSLC400FS in the Safety Logic Controller TM5CSLCx00FS Hardware Guide).
Procedure in Logic Builder:
Step |
Action |
---|---|
1 |
Log in to the Logic/Motion Controller ( ). Result: Open editors are switched to online mode. |
2 |
If the application is not running, start the application execution by selecting the command or pressing . |
3 |
|
4 |
Expand the folder and double-click the node.Result: The visualization worksheet opens showing the virtual SLC control center. |
5 |
In the virtual SLC control center, click the button and then the button. |
6 |
Enter the SLC password into the field below the button and press . Result: The data shown in the visualization screen are read from the SLC and displayed on your screen. |
If you have executed the Application Download command via the visualization, you must confirm the project CRC. Machine Expert - Safety shows this CRC as hexadecimal value (for example, in the dialog). The visualization in Logic Builder may expect a decimal value. You can set format via context menu of the visualization page.
Refer to the EcoStruxure Machine Expert - Safety Programming Guide for information on the Application Download feature.