The motors are equipped with a HIPERFACE DSL encoder. The drive can access the electronic nameplate via the HIPERFACE interface for commissioning.
The circuits meet PELV requirements.
This motor encoder measures an absolute value within one revolution at start-up and continues to count incrementally from this point.
Characteristic |
Value |
---|---|
Resolution per revolution |
18 bit |
Measuring range absolute |
1 revolution |
Signal shape |
Digital |
Temperature sensor |
Integrated |
Supply voltage |
7 ... 12 Vdc |
Maximum angular acceleration |
200000 rad/s2 |
This motor encoder measures an absolute value within 4096 revolutions at start-up and continues to count incrementally from this point.
Characteristic |
Value |
---|---|
Resolution per revolution |
18 bit |
Measuring range absolute |
4096 revolutions |
Signal shape |
Digital |
Temperature sensor |
Integrated |
Supply voltage |
7 ... 12 Vdc |
Maximum angular acceleration |
200000 rad/s2 |
This motor encoder measures an absolute value within one revolution at start-up and continues to count incrementally from this point.
Characteristic |
Value |
---|---|
Resolution per revolution |
15 bit |
Measuring range absolute |
1 revolution |
Signal shape |
Digital |
Temperature sensor |
Integrated |
Supply voltage |
7 ... 12 Vdc |
Maximum angular acceleration |
200000 rad/s2 |
This motor encoder measures an absolute value within 4096 revolutions at start-up and continues to count incrementally from this point.
Characteristic |
Value |
---|---|
Resolution per revolution |
15 bit |
Measuring range absolute |
4096 revolutions |
Signal shape |
Digital |
Temperature sensor |
Integrated |
Supply voltage |
7 ... 12 Vdc |
Maximum angular acceleration |
200000 rad/s2 |