FUNCTION_BLOCK IoDrvEtherNetIP EXTENDS IoDrvBase IMPLEMENTS ICmpIoDrvParameter, IScanner, IoDrvEtherNetIPAdapter.IScannerExtension, CmpEventMgr.ICmpEventCallback
Driver FB: Don´t create this FB directly.
Following Vendor specific cip objects are implemented for the scanner:
Class 0x300 ConsumingAssemblyManager: read consuming I/O data (O–>T) from the connection of each remote adapter
Attribute
ID
Datatype
Instance 0
Revision
1
UINT
NumOfRemoteAdapter
2
UINT
Instance X (Index of remote adapter in device tree starting by 1)
List of Assemblies
1
Amount of Assemblies and Array of InstanceID (UDINT + N*UDINT)
Data of Assembly
N (Index of list)
ARRAY of octet
Class 0x301 ProducingAssemblyManager: read producing I/O data (T–>O) from the connection of each remote adapter
Attribute
ID
Datatype
Instance 0
Revision
1
UINT
NumOfRemoteAdapter
2
UINT
Instance X (Index of remote adapter in device tree starting by 1)
List of Assemblies
1
Amount of Assemblies and Array of InstanceID (UDINT + N*UDINT)
Data of Assembly
N (Index of list)
ARRAY of octet
| InOut: |
|
Properties:
Methods:
Structure: