Function block to control a Lexium P Robot.
The initialization is performed with the inherited methods SERP.InitializeRobot, SERP.InitializeRotationalAxisSERP.InitializeRotationalAxis, SERP.OptionalEquipmentSERP.OptionalEquipment and SetKinematicParameter.
|
q_etDiag |
q_etDiagExt |
Enumeration value |
Description |
|---|---|---|---|
|
OK |
DriveSuccessfulPrepared |
13 |
The drive is successfully prepared. |
|
OK |
VirtualDrives |
11 |
The drives are virtual. |
|
ConfigurationFailed |
DriveNotPrepared |
14 |
The drive is not prepared. |
|
ExecutionAborted |
BrakeCouplingTimeInvalid |
80 |
The BrakeCouplingTime is invalid. |
|
ExecutionAborted |
BrakeDisconnectionTimeInvalid |
79 |
The BrakeDisconnectionTime is invalid. |
|
ExecutionAborted |
BrakeIntegratedInvalid |
67 |
BrakeIntegrated is invalid. |
|
ExecutionAborted |
ControllerStopDecInvalid |
78 |
ControllerStopDec is invalid. |
|
ExecutionAborted |
ControllerStopJerkInvalid |
77 |
ControllerStopJerk is invalid. |
|
ExecutionAborted |
ControlModeInvalid |
72 |
The ControlMode is invalid. |
|
ExecutionAborted |
DirectionInvalid |
64 |
The Direction is invalid. |
|
ExecutionAborted |
DriveInvalid |
5 |
The drive is invalid. |
|
ExecutionAborted |
DriveStopCurrentLimitInvalid |
92 |
DriveStopCurrentLimit is invalid. |
|
ExecutionAborted |
EncoderDirectionInvalid |
75 |
The EncoderDirection is invalid. |
|
ExecutionAborted |
EncoderGearInInvalid |
73 |
The EncoderGearIn is invalid. |
|
ExecutionAborted |
EncoderGearOutInvalid |
74 |
The EncoderGearOut is invalid. |
|
ExecutionAborted |
EncoderRangeInvalid |
68 |
The EncoderRange is invalid. |
|
ExecutionAborted |
FeedConstantInvalid |
65 |
The FeedConstant is invalid. |
|
ExecutionAborted |
GearInInvalid |
62 |
The GearIn is invalid. |
|
ExecutionAborted |
GearOutInvalid |
63 |
The GearOut is invalid. |
|
ExecutionAborted |
InterfaceInvalid |
3 |
The Interface is invalid. |
|
ExecutionAborted |
MissingProgramCall |
32 |
The program call is unavailable. |
|
ExecutionAborted |
MotorIdentification |
76 |
The MotorIdentification is invalid. |
|
ExecutionAborted |
MotorTypeInvalid |
66 |
The MotorType is invalid. |
|
ExecutionAborted |
StaticFrictionInvalid |
81 |
StaticFriction is invalid. |
|
ExecutionAborted |
TaskIntervalInvalid |
31 |
The interval of the task is invalid. |
|
ExecutionAborted |
UserDefinedStopModeInvalid |
93 |
UserDefinedStopMode is invalid. |
|
ExecutionAborted |
UserDrivePeakCurrentInvalid |
71 |
The UserDrivePeakCurrent is invalid. |
|
ExecutionAborted |
ViscousFrictionInvalid |
82 |
ViscousFriction is invalid. |
|
ExecutionAborted |
WorkingStateInvalid |
70 |
The WorkingState is invalid. |
|
ExecutionAborted |
YOffsetEnableInvalid |
83 |
YOffsetEnable is invalid. |
|
Enumeration name: |
BrakeCouplingTimeInvalid |
|
Enumeration value: |
80 |
|
Description: |
The BrakeCouplingTime is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter BrakeCouplingTime of the drive is invalid. |
The parameter BrakeCouplingTime has been adapted. |
See property sMsg for expected value. |
|
Enumeration name: |
BrakeDisconnectionTimeInvalid |
|
Enumeration value: |
79 |
|
Description: |
The BrakeDisconnectionTime is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter BrakeDisconnectionTime of the drive is invalid. |
The parameter BrakeDisconnectionTime has been adapted. |
See property sMsg for expected value. |
|
Enumeration name: |
BrakeIntegratedInvalid |
|
Enumeration value: |
67 |
|
Description: |
BrakeIntegrated is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter BrakeIntegrated of the drive is invalid. |
The parameter BrakeIntegrated has been adapted. |
See property sMsg for expected value. |
|
Enumeration name: |
ControllerStopDecInvalid |
|
Enumeration value: |
78 |
|
Description: |
ControllerStopDec is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter ControllerStopDec of the drive is invalid |
The parameter ControllerStopDec has been adapted. |
See property sMsg for expected value. |
|
Enumeration name: |
ControllerStopJerkInvalid |
|
Enumeration value: |
77 |
|
Description: |
ControllerStopJerk is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter ControllerStopJerk of the drive is invalid |
The parameter ControllerStopJerk has been adapted. |
See property sMsg for expected value. |
|
Enumeration name: |
ControlModeInvalid |
|
Enumeration value: |
72 |
|
Description: |
The ControlMode is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter ControlMode of the drive is invalid |
The parameter ControlMode of the drive has been adapted. |
See property sMsg for expected value. |
|
Enumeration name: |
DirectionInvalid |
|
Enumeration value: |
64 |
|
Description: |
The Direction is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter Direction of the drive is invalid |
The parameter Direction of the drive has been adapted. |
See property sMsg for expected value. |
|
Enumeration name: |
DriveInvalid |
|
Enumeration value: |
5 |
|
Description: |
The drive is invalid. |
An invalid drive has been configured.
|
Enumeration name: |
DriveNotPrepared |
|
Enumeration value: |
14 |
|
Description: |
The drive is not prepared. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
Drive is not prepared for execution. |
'P-0-1069.0.0' is unavailable in parameter AdditionalIDNListMDT of the drive. |
Write 'P-0-1069.0.0' to parameter AdditionalIDNListMDT of the drive. |
|
Enumeration name: |
DriveStopCurrentLimitInvalid |
|
Enumeration value: |
92 |
|
Description: |
DriveStopCurrentLimit is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter DriveStopCurrentLimitInvalid of the drive is invalid. |
The parameter DriveStopCurrentLimitInvalid of the drive has been adapted. |
See property sMsg for expected value. |
|
Enumeration name: |
DriveSuccessfulPrepared |
|
Enumeration value: |
13 |
|
Description: |
The drive is successfully prepared. |
The drive is successfully prepared for execution.
|
Enumeration name: |
EncoderDirectionInvalid |
|
Enumeration value: |
75 |
|
Description: |
The EncoderDirection is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter EncoderDirection of the drive is invalid |
The parameter EncoderDirection of the drive has been adapted. |
See property sMsg for expected value. |
|
Enumeration name: |
EncoderGearInInvalid |
|
Enumeration value: |
73 |
|
Description: |
The EncoderGearIn is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter EncoderGearIn of the drive is invalid |
The parameter EncoderGearIn of the drive has been adapted. |
See property sMsg for expected value. |
|
Enumeration name: |
EncoderGearOutInvalid |
|
Enumeration value: |
74 |
|
Description: |
The EncoderGearOut is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter EncoderGearOut of the drive is invalid |
The parameter EncoderGearOut of the drive has been adapted. |
See property sMsg for expected value. |
|
Enumeration name: |
EncoderRangeInvalid |
|
Enumeration value: |
68 |
|
Description: |
The EncoderRange is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter EncoderRange of the drive is invalid |
The parameter EncoderRange of the drive has been adapted. |
See property sMsg for expected value. |
|
Enumeration name: |
FeedConstantInvalid |
|
Enumeration value: |
65 |
|
Description: |
The FeedConstant is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter FeedConstant of the drive is invalid |
The parameter FeedConstant of the drive has been adapted. |
See property sMsg for expected value. |
|
Enumeration name: |
GearInInvalid |
|
Enumeration value: |
62 |
|
Description: |
The GearIn is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter GearIn of the drive is invalid |
The parameter GearIn of the drive has been adapted. |
See property sMsg for expected value. |
|
Enumeration name: |
GearOutInvalid |
|
Enumeration value: |
63 |
|
Description: |
The GearOut is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter GearOut of the drive is invalid |
The parameter GearOut of the drive has been adapted. |
See property sMsg for expected value. |
|
Enumeration name: |
InterfaceInvalid |
|
Enumeration value: |
3 |
|
Description: |
The Interface is invalid. |
An incorrect program behavior occurred. An interface is invalid.
|
Enumeration name: |
MissingProgramCall |
|
Enumeration value: |
32 |
|
Description: |
The program call is unavailable. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The program call is unavailable. |
The program SR_SlowCyclicExecution is not called in a cyclic task. |
Ensure that the program SR_SlowCyclicExecution is called in a cyclic task. |
|
Enumeration name: |
MotorIdentification |
|
Enumeration value: |
76 |
|
Description: |
The MotorIdentification is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter MotorIdentification of a drive is invalid. |
The parameter MotorIdentification of a drive is different to the MotorIdentification of the other drives of the robot. |
Ensure that all drives used for one robot have the same value for the parameter MotorIdentification. |
|
Enumeration name: |
MotorTypeInvalid |
|
Enumeration value: |
66 |
|
Description: |
The MotorType is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter MotorType of the drive is invalid |
The parameter MotorType of the drive has been adapted. |
See property sMsg for expected value. |
|
Enumeration name: |
StaticFrictionInvalid |
|
Enumeration value: |
81 |
|
Description: |
StaticFriction is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter StaticFriction of the drive is invalid. |
The parameter StaticFriction is <> 0. |
Ensure that the parameter StaticFriction is 0. |
|
Enumeration name: |
TaskIntervalInvalid |
|
Enumeration value: |
31 |
|
Description: |
The interval of the task is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
SR_SlowCyclicExecution is called with an invalid task interval. |
The task that calls SR_SlowCyclicExecution has an invalid task interval. |
Ensure that SR_SlowCyclicExecution is called in a task with 10 ms interval. |
|
Enumeration name: |
UserDefinedStopModeInvalid |
|
Enumeration value: |
93 |
|
Description: |
UserDefinedStopMode is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter UserDefinedStopMode of the drive is invalid. |
The parameter UserDefinedStopMode of the drive has been adapted. |
See property sMsg for expected value. |
|
Enumeration name: |
UserDrivePeakCurrentInvalid |
|
Enumeration value: |
71 |
|
Description: |
The UserDrivePeakCurrent is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter UserDrivePeakCurrent of the drive is invalid. |
The parameter UserDrivePeakCurrent of the drive has been adapted. |
See property sMsg for expected value. |
|
Enumeration name: |
VirtualDrives |
|
Enumeration value: |
11 |
|
Description: |
The drives are virtual. |
Drives are virtual.
|
Enumeration name: |
ViscousFrictionInvalid |
|
Enumeration value: |
82 |
|
Description: |
ViscousFriction is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter StaticFriction of the drive is invalid. |
The parameter StaticFriction is <> 0. |
Ensure that the parameter StaticFriction is 0. |
|
Enumeration name: |
WorkingStateInvalid |
|
Enumeration value: |
70 |
|
Description: |
The WorkingState is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter WorkingState of a drive is invalid. |
The parameter WorkingState of a drive is different to the WorkingState of the other drives of the robot. |
Ensure that all drives used for one robot have the same value for the parameter WorkingState. |
|
Enumeration name: |
YOffsetEnableInvalid |
|
Enumeration value: |
83 |
|
Description: |
YOffsetEnable is invalid. |
|
Issue |
Cause |
Solution |
|---|---|---|
|
The parameter YOffsetEnable is invalid. |
YOffsetEnable is active. |
Ensure that the parameter YOffsetEnable is not used. |
|
Name |
Description |
|---|---|
|
GetControlLoopParameter |
Read the parameter, which influences the control loop of the Lexium P Robot axes. |
|
GetKinematicParameter |
Read kinematic parameter for a Lexium P Robot. |
|
RegisterLoggerPoint |
Register the FB_RobotPSeries to the Application Logger. |
|
SetControlLoopParameter |
Set parameter to influence the control loop of the Lexium P Robot axes. |
|
CheckPositionInWorkEnvelope |
Verify whether a given coordinate is inside the robot work envelope. |
|
SetDigitalTwinConfigData |
Set the configuration data for the EcoStruxure Machine Expert Twin communication of the Lexium P Robot. |
|
GetDigitalTwinConfigData |
Read the configuration data for the EcoStruxure Machine Expert Twin communication of the Lexium P Robot. |
|
GetRobotData |
Read the parameters of the configured robot type. |
|
SetKinematicParameter |
Set kinematic parameter for a Lexium P Robot. |
|
Name |
Description |
|---|---|
|
InitializeRobot |
Initialize the robot and its axes. |
|
InitializeRotationalAxis |
Initialize the rotational axis of the robot, if necessary. |
|
OptionalEquipment |
Set optional equipment of the robot. |
|
Name |
Data type |
Accessing |
Description |
|---|---|---|---|
|
etDiag |
Read |
General library-independent statement of the diagnostic. A value not equal to GD.ET_Diag.Ok corresponds to a diagnostic message. |
|
|
etDiagExt |
Read |
POU-specific output on the diagnostic. q_etDiag = GD.ET_Diag.Ok -> Status message q_etDiag <> GD.ET_Diag.Ok -> Diagnostic message |
|
|
etRotationalAxis |
Read |
Get the ET_RobotComponent.AuxAx that was used for the rotational axis. |
|
|
ifCalibration |
Read |
Get the interface to execute calibration modes. |
|
|
ifFastMove |
SER.IF_FastMove |
Get |
The property returns an interface of the type SER.IF_FastMove that can be used to configure and control the feature FastMoveFastMove. |
|
ifFeedback |
Read |
Get the interface of a Lexium P Robot to retrieve calculated values of a virtual motor. |
|
|
ifSchneiderElectricRobot |
ROB.IF_SchneiderElectricRobot |
Read |
Get the interface for the configuration method ROB.IF_RobotConfiguration.SchneiderElectricRobot |
|
sMsg |
STRING[80] |
Read |
Event-triggered message that gives more information on the diagnostic state. |
|
xAxesConfigured |
BOOL |
Read |
TRUE: The axes have been configured successfully. |
|
xDiagQuit |
BOOL |
Read/Write |
A rising edge FALSE->TRUE acknowledges diagnostic messages. |
|
xDisableWorkEnvelopeMoveCmds |
BOOL |
Read/Write |
TRUE: Disable the verification of target, circular, and spline points when sending move commands to the robot. Default value: FALSE In case of xDisableWorkEnvelopeMoveCmds activated and the robot is outside the work envelope, the robot accepts the move commands and returns ET_Diag = Ok. The robot starts the movement but will immediately stop. |
|
xRobotInWorkEnvelope |
BOOL |
Read |
The bit can be used to verify if the robot TCP is inside the work envelope. TRUE: The robot TCP is inside the work envelope. FALSE: The robot TCP is outside the work envelope. The feedback is updated in the task SR_SlowCyclicExecution. Therefore, there might be a delay of a few ms until the property shows the correct value. |