El tipo de datos de enumeración evtlog_appMsgId contiene los siguientes valores:
Enumerador |
Tipo |
Valor |
Comentario |
---|---|---|---|
EVTLOG_INVALID_APPMSG_ID |
INT |
-1 |
– |
EVTLOG_CONNECTION_SUCCESS |
INT |
0 |
CONNECTION_SUCCESS - 0x001 |
EVTLOG_CONNECTION_INVALID_CREDENTIAL_EXPIRED_CERTIFICATE |
INT |
1 |
CONNECTION_INVALID_CREDENTIAL - 0x002 |
EVTLOG_CONNECTION_INVALID_CREDENTIAL_REVOKED_CERTIFICATE |
INT |
2 |
CONNECTION_INVALID_CREDENTIAL - 0x002 |
EVTLOG_CONNECTION_INVALID_CREDENTIAL_OUTDATED_PASSWORD |
INT |
3 |
CONNECTION_INVALID_CREDENTIAL - 0x002 |
EVTLOG_CONNECTION_FAILURE_INVALID_CERTIFICATE |
INT |
4 |
CONNECTION_FAILURE - 0x003 |
EVTLOG_CONNECTION_FAILURE_INVALID_PASSWORD |
INT |
5 |
CONNECTION_FAILURE - 0x003 |
EVTLOG_CONNECTION_FAILURE_UNKNOWN_USER |
INT |
6 |
CONNECTION_FAILURE - 0x003 |
EVTLOG_CONNECTION_FAILURE_MAX_CONNECTIONS_REACHED |
INT |
7 |
CONNECTION_FAILURE - 0x003 |
EVTLOG_CONNECTION_FAILURE_FILTERED_DATA_FLOW |
INT |
8 |
CONNECTION_FAILURE - 0x003 |
EVTLOG_CONNECTION_FAILURE_AND_BLOCK_INVALID_CERTIFICATE |
INT |
9 |
CONNECTION_FAILURE_AND_BLOCK - 0X004 |
EVTLOG_CONNECTION_FAILURE_AND_BLOCK_INALID_PASSWORD |
INT |
10 |
CONNECTION_FAILURE_AND_BLOCK - 0x004 |
EVTLOG_CONNECTION_FAILURE_ON_BLOCKED |
INT |
11 |
CONNECTION_FAILURE_ON_BLOCKED - 0x005 |
EVTLOG_DISCONNECTION_MANUAL_LOGOUT |
INT |
12 |
DISCONNECTION - 0x006 |
EVTLOG_DISCONNECTION_TIMEOUT_LOGOUT |
INT |
13 |
DISCONNECTION - 0x006 |
EVTLOG_DISCONNECTION_SOCKET |
INT |
14 |
DISCONNECTION - 0x006 |
EVTLOG_OPERATION_UNAUTHORIZED |
INT |
15 |
OPERATION UNAUTHORIZED - 0X101 |
EVTLOG_OPERATION_AUTHORIZED |
INT |
16 |
OPERATION AUTHORIZED - 0x102 |
EVTLOG_OPERATION_AUTHORIZED_FORWARDED |
INT |
17 |
OPERATION_AUTHORIZED_FORWARDED - 0x103 |
EVTLOG_FIRMWARE_UPDATE |
INT |
18 |
FIRMWARE UPDATE - 0x201 |
EVTLOG_FIRMWARE_INVALID_FORMAT |
INT |
19 |
FIRMWARE INVALID - 0x202 |
EVTLOG_FIRMWARE_INVALID_INCOMPATIBLE_VERSION |
INT |
20 |
FIRMWARE INVALID - 0x202 |
EVTLOG_FIRMWARE_INVALID_UNAUTHENTICATED_ORIGIN |
INT |
21 |
FIRMWARE INVALID - 0x202 |
EVTLOG_FIRMWARE_INVALID_INVALID_SIGNATURE |
INT |
22 |
FIRMWARE INVALID - 0x202 |
EVTLOG_FIRMWARE_INVALID_ROLLBACK_OPERATION_DETECTED |
INT |
23 |
FIRMWARE INVALID - 0x202 |
EVTLOG_FIRMWARE_INVALID_INVALID_SOFTWARE_CODE |
INT |
24 |
FIRMWARE INVALID - 0x202 |
EVTLOG_CS_CONFIGURATION_CHANGE |
INT |
25 |
CS CONFIGURATION CHANGE - 0x203 |
EVTLOG_CS_CONFIGURATION_ACCESS |
INT |
26 |
CS_CONFIGURATION_ACCESS - 0x204 |
EVTLOG_CS_CONFIGURATION_USE_ATTEMPT_INVALID_CERTIFICATE |
INT |
27 |
CS_CONFIGURATION_USE_ATTEMPT -0x205 |
EVTLOG_CS_CONFIGURATION_USE_ATTEMPT_INVALID_SOFTWARE |
INT |
28 |
CS_CONFIGURATION_USE_ATTEMPT -0x205 |
EVTLOG_CS_CONFIGURATION_INVALID_INVALID_FORMAT |
INT |
29 |
CS_CONFIGURATION_INVALID - 0x206 |
EVTLOG_CS_CONFIGURATION_INVALID_INCOMPATIBLE_VERSION |
INT |
30 |
CS_CONFIGURATION_INVALID - 0x206 |
EVTLOG_CS_CONFIGURATION_INVALID_UNAUTHENTICATED_ORIGIN |
INT |
31 |
CS_CONFIGURATION_INVALID - 0x206 |
EVTLOG_CS_CONFIGURATION_INVALID_SIGNATURE |
INT |
32 |
CS_CONFIGURATION_INVALID - 0x206 |
EVTLOG_CS_CONFIGURATION_INVALID_ROLLBACK_OPERATION_DETECTED |
INT |
33 |
CS_CONFIGURATION_INVALID - 0x206 |
EVTLOG_TIME_CHANGE |
INT |
34 |
TIME_CHANGE - 0x207 |
EVTLOG_TIME_UNEXPECTED |
INT |
35 |
TIME UNEXPECTED - 0x208 |
EVTLOG_VALUE_FORCING |
INT |
36 |
VALUE FORCING - 0x209 |
EVTLOG_CONFIGURATION_CHANGE |
INT |
37 |
CONFIGURATION_CHANGE - 0x20A |
EVTLOG_CONFIGURATION_ACCESS |
INT |
38 |
CONFIGURATION_ACCESS - 0x20B |
EVTLOG_CONFIGURATION_INVALID_INVALID_FORMAT |
INT |
39 |
CONFIGURATION INVALID - 0x20C |
EVTLOG_CONFIGURATION_INVALID_INCOMPATIBLE_VERSION |
INT |
40 |
CONFIGURATION INVALID - 0x20C |
EVTLOG_CONFIGURATION_INVALID_UNAUTHENTICATED_ORIGIN |
INT |
41 |
CONFIGURATION INVALID - 0x20C |
EVTLOG_CONFIGURATION_INVALID_INVALID_SIGNATURE |
INT |
42 |
CONFIGURATION INVALID - 0x20C |
EVTLOG_CONFIGURATION_INVALID_ROLLBACK_OPERATION_DETECTED |
INT |
43 |
CONFIGURATION INVALID - 0x20C |
EVTLOG_CODE_INVALID_INVALID_FORMAT |
INT |
44 |
CODE_INVALID-0x20D |
EVTLOG_CODE_INVALID_INCOMPATIBLE_VERSION |
INT |
45 |
CODE_INVALID-0x20D |
EVTLOG_CODE_INVALID_UNAUTHENTICATED_ORIGIN |
INT |
46 |
CODE_INVALID-0x20D |
EVTLOG_CODE_INVALID_INVALID_SIGNATURE |
INT |
47 |
CODE_INVALID-0x20D |
EVTLOG_CODE_INVALID_ROLLBACK_OPERATION_DETECTED |
INT |
48 |
CODE_INVALID-0x20D |
EVTLOG_SEC_LOGS_ACCESS |
INT |
49 |
SEC_LOGS_ACCESS - 0x301 |
EVTLOG_AUDIT_STORAGE_NEARLY_FULL_LESS_ABSOLUTE |
INT |
50 |
AUDIT_STORAGE_NEARLY_FULL - 0x302 |
EVTLOG_AUDIT_STORAGE_NEARLY_FULL_LESS_PERCENT |
INT |
51 |
AUDIT_STORAGE_NEARLY_FULL - 0x302 |
EVTLOG_AUDIT_PROCESSING_FAILURE_NO_MORE_SPACE |
INT |
52 |
AUDIT_PROCESSING_FAILURE - 0x303 |
EVTLOG_AUDIT_PROCESSING_FAILURE_SERVER_DISCONNECTED |
INT |
53 |
AUDIT_PROCESSING_FAILURE - 0x303 |
EVTLOG_MARK |
INT |
54 |
MARK - 0x304 |
EVTLOG_REBOOT_FIRMWARE_UPDATE |
INT |
55 |
REBOOT - 0x401 |
EVTLOG_REBOOT_RESET_BUTTON |
INT |
56 |
REBOOT - 0x401 |
EVTLOG_REBOOT_REMOTE_ORDER |
INT |
57 |
REBOOT - 0x401 |
EVTLOG_STARTUP |
INT |
58 |
STARTUP - 0x402 |
EVTLOG_OPERATING_MODE_CHANGE_INIT |
INT |
59 |
OPERATING MODE CHANGE - 0x403 |
EVTLOG_OPERATING_MODE_CHANGE_RUN |
INT |
60 |
OPERATING MODE CHANGE - 0x403 |
EVTLOG_OPERATING_MODE_CHANGE_STOP |
INT |
61 |
OPERATING MODE CHANGE - 0x403 |
EVTLOG_HARDWARE_CHANGE_PORT_LINK_UP |
INT |
62 |
HARDWARE_CHANGE - 0x404 |
EVTLOG_HARDWARE_CHANGE_PORT_LINK_DOWN |
INT |
63 |
HARDWARE_CHANGE - 0x404 |
EVTLOG_HARDWARE_INVALID_MODULE_INSERTED |
INT |
64 |
HARDWARE INVALID - 0x405 |
EVTLOG_HARDWARE_INVALID_USB_KEY_NOT_SUPPORTED |
INT |
65 |
HARDWARE INVALID - 0x405 |
EVTLOG_TAMPERING_PHYS_TAMPER_DETECTION |
INT |
66 |
TAMPERING - 0x406 |
EVTLOG_TAMPERING_SECURE_BOOT_FAILURE |
INT |
67 |
TAMPERING - 0x406 |
EVTLOG_TAMPERING_CODE_TAMPER_DETECTION |
INT |
68 |
TAMPERING - 0x406 |
EVTLOG_TAMPERING_FIRMWARE_TAMPER_DETECTION |
INT |
69 |
TAMPERING - 0x406 |
EVTLOG_TAMPERING_INVALID_INTERNAL_DATA |
INT |
70 |
TAMPERING - 0x406 |
EVTLOG_SHUTDOWN_BUTTON |
INT |
71 |
SHUTDOWN - 0x407 |
EVTLOG_SHUTDOWN_REMOTE_ORDER |
INT |
72 |
SHUTDOWN - 0x407 |
EVTLOG_USERACCOUNT_CHANGE_CREATION |
INT |
73 |
USERACCOUNT CHANGE - 0x501 |
EVTLOG_USERACCOUNT_CHANGE_MODIFICATION |
INT |
74 |
USERACCOUNT CHANGE - 0x501 |
EVTLOG_USERACCOUNT_CHANGE_DELETION |
INT |
75 |
USERACCOUNT CHANGE - 0x501 |
EVTLOG_USERACCOUNT_CHANGE_PASSWORD_UPDATE |
INT |
76 |
USERACCOUNT CHANGE - 0x501 |
EVTLOG_USERACCOUNT_CHANGE_PASSWORD_RESET |
INT |
77 |
USERACCOUNT CHANGE - 0x501 |
EVTLOG_CERTIFICATE_CHANGE_CREATION |
INT |
78 |
CERTIFICATE CHANGE - 0x502 |
EVTLOG_CERTIFICATE_CHANGE_RENEWAL |
INT |
79 |
CERTIFICATE CHANGE - 0x502 |
EVTLOG_CERTIFICATE_CHANGE_DELETION |
INT |
80 |
CERTIFICATE CHANGE - 0x502 |
EVTLOG_CERTIFICATE_CHANGE_KEY_CREATION |
INT |
81 |
CERTIFICATE CHANGE - 0x502 |
EVTLOG_CERTIFICATE_CHANGE_KEY_RENEWAL |
INT |
82 |
CERTIFICATE CHANGE - 0x502 |
EVTLOG_CERTIFICATE_CHANGE_KEY_DELETION |
INT |
83 |
CERTIFICATE CHANGE - 0x502 |
EVTLOG_CERTIFICATE_CHANGE_ADDITION_IN_TRUSTLIST |
INT |
84 |
CERTIFICATE CHANGE - 0x502 |
EVTLOG_CERTIFICATE_CHANGE_REMOVAL_FROM_TRUSTLIST |
INT |
85 |
CERTIFICATE CHANGE - 0x502 |
EVTLOG_CERTIFICATE_ENROLMENT_FAILURE_CA_NOT_REACHABLE |
INT |
86 |
CERTIFICATE_ENROLLMENT_FAILURE - 0x503 |
EVTLOG_CERTIFICATE_ENROLMENT_FAILURE_CRL_DISTRIBUTION_POINT_NOT_REACHABLE |
INT |
87 |
CERTIFICATE_ENROLLMENT_FAILURE - 0x503 |
EVTLOG_CERTIFICATE_ENROLMENT_FAILURE_CRL_CANT_BE_STORED |
INT |
88 |
CERTIFICATE_ENROLLMENT_FAILURE - 0x503 |
EVTLOG_CERTIFICATE_ENROLMENT_FAILURE_FAILURE_FROM_CA |
INT |
89 |
CERTIFICATE_ENROLLMENT_FAILURE - 0x503 |
EVTLOG_CERTIFICATE_ENROLMENT_FAILURE_TRUSTLIST_CANT_BE_STORED |
INT |
90 |
CERTIFICATE_ENROLLMENT_FAILURE - 0x503 |
EVTLOG_CERTIFICATE_ENROLMENT_FAILURE_CERTIFICATE_CANT_BE_STORED |
INT |
91 |
CERTIFICATE_ENROLLMENT_FAILURE - 0x503 |
EVTLOG_CERTIFICATE_ABOUT_TO_EXPIRE_CERT_LIFETIME_THRESHOLD |
INT |
92 |
CERTIFICATE_ABOUT_TO_EXPIRE - 0x504 |
EVTLOG_CERTIFICATE_ABOUT_TO_EXPIRE_KEYS_LIFETIME_THRESHOLD |
INT |
93 |
CERTIFICATE_ABOUT_TO_EXPIRE - 0x504 |
EVTLOG_CERTIFICATE_EXPIRED_CERT_EXPIRATION |
INT |
94 |
CERTIFICATE_EXPIRED - 0x505 |
EVTLOG_CERTIFICATE_EXPIRED_KEYS_EXPIRATION |
INT |
95 |
CERTIFICATE_EXPIRED - 0x505 |
EVTLOG_BACKUP |
INT |
96 |
BACKUP - 0x601 |
EVTLOG_RESTORE |
INT |
97 |
RESTORE - 0x602 |
EVTLOG_APPMSG_ID_CTI13_MAX |
INT |
98 |
– |