The following explanation only refers to standard stations (for more information refer to Standard stations or for example to FB_ClampingStation, FB_DeclampingStation or FB_GroupingStation):
By setting the property xEnable to TRUE, the function block starts the enabling process. The function block continues initialization and the property xActive is set to TRUE. Once the initialization is finished and no error is active, the property xReady is set to TRUE.
If an error occurs, the property xError indicates TRUE and remains TRUE until the function block is disabled.
The methods of the function block FB_CoreStation provide the following common outputs:
|
Output |
Data type |
Description |
|---|---|---|
|
q_xError |
BOOL |
Indicates TRUE if an error has been detected. For details, refer to q_etResult and q_sResultMsg. |
|
q_etResult |
Provides diagnostic and status information as a numeric value. |
|
|
q_sResultMsg |
STRING [255] |
Provides additional diagnostic and status information as a text message. |
The standard stations provide the following common properties:
|
Name |
Data type |
Accessing |
Description |
|---|---|---|---|
|
etResult |
Read |
Provides diagnostic and status information as a numeric value.
If xError = FALSE, etResult provides status information. |
|
|
sResultMsg |
STRING [255] |
Read |
The event-triggered property sResultMsg provides additional diagnostic and status information as a text message. |
|
xActive |
BOOL |
Read |
Indicates TRUE if the function block is active. |
|
xEnable |
BOOL |
Write |
If xEnable is set to TRUE, the station is enabled (activated). |
|
xError |
BOOL |
Read |
Indicates TRUE if an error has been detected. For details, refer to etResult and sResultMsg. |
|
xErrorQuit |
BOOL |
Write |
When an error is detected, state machine is going to a WAITING state. If xErrorQuit is set to TRUE, you leave this WAITING state and reset the error variables. |
|
xReady |
BOOL |
Read |
Indicates TRUE if the function block is enabled and no error is active. Indicates FALSE if the function block is enabled and an error is active or if the function block is disabled. |