ST_Positioning

 

ST_Positioning - General Information

Overview

Type:

Data structure

Available as of:

V1.0.2.0

Inherits from:

-

Versions:

Current version

Description

In this structure the parameters and the return values of the operating mode Positioning of the FB_AxisModule are summarized.

Structure Elements

Variable

Data type

Description

i_etPosMode

SystemInterface.ET_PosMode

Positioning mode. See PDL.FB_VarioPosJerk.

i_lrTarget

LREAL

Target or distance of the positioning. See PDL.FB_VarioPosJerk.

i_lrVel

LREAL

Positioning velocity. See PDL.FB_VarioPosJerk.

i_lrAcc

LREAL

Positioning acceleration. See PDL.FB_VarioPosJerk.

i_lrDec

LREAL

Positioning delay. See PDL.FB_VarioPosJerk.

i_lrJerk

LREAL

Positioning jerk. See PDL.FB_VarioPosJerk.

i_xStop

BOOL

Positioning stop. See PDL.FB_VarioPosJerk.

q_xInPosition

BOOL

Target position reached. See PDL.FB_VarioPosJerk.