Product Overview

General Description of the

The  is a cantilever axis, which can operate forward and backward in one dimension. The axis with rod design is based on an axis body and a guide with linear ball bearings.

Depending on the size of the particular axis, a  is driven by a gear rack or a toothed belt.

Components Overview

Axis with gear rack mechanical drive

Axis with toothed belt mechanical drive

G-SE-0058337.2.gif-high.gif

 

 

 

1   End plate

2   Guide rod

3   Shaft extension

4   Linear ball bearing

5   Axis body

6   Contact block

7   Gear rack

8   Slide bearing

9   Toothed belt

10   Rubber buffer

11   Sensor (optional equipment)

12   Axis body adapter plate

13   Coupling housing including coupling (optional equipment)

14   Gearbox adaptation (optional equipment)

15   Gearbox (optional equipment)

16   Motor adaptation (optional equipment)

17   Motor (optional equipment)

18   Toothed belt tensioner

Characteristics of the

The axis provides the following features and options:

oHigh rigidity for short strokes

oLow moving mass

oCompact installation space

oDifferent stroke lengths available

oLubricated for life

oEasy integration into machines and systems

oMotor and gearbox mounting via compact coupling systems

oFastening threads with counterbores for locating dowels at the end plates for reproducible mounting of the payload

oOptions

oAntistatic toothed belt

oIncreased corrosion resistance

oSensors as normally open contacts / normally closed contacts and NPN/PNP version

oDifferent motors and gearboxes

Types of Mechanical Drive Elements

Two elements to drive the axis are available for the . The following table presents the particular axis and the corresponding mechanical drive element. For a detailed name description of the , refer to Type Code.

Gear rack

Toothed belt

Lexium CAR40RC

Lexium CAR41BC

Lexium CAR42BC

Lexium CAR43BC

Lexium CAR44BC

Types of Linear Guides

All sizes of the  are equipped with linear ball bearings, except the Lexium CAR40 which has both linear ball bearings and slide bearings. For a detailed name description of the , refer to Type Code.

Gear rack

Toothed belt

Lexium CAR40RC

Lexium CAR41BC

Lexium CAR42BC

Lexium CAR43BC

Lexium CAR44BC

Mounting Options for the Motor and/or Gearbox

The following figure presents the mounting options for the motor and/or gearbox for the .

G-SE-0065047.2.gif-high.gif

 

1   Motor and/or gearbox mounted on right-hand side

2   Adaptation material mounted on right-hand side

3   Without motor or gearbox

Mounting Direction of the Motor and Gearbox

The following figure presents the possible mounting direction of the motor and gearbox combinations. The motor or the gearbox is coupled by using a preloaded elastomer coupling.

G-SE-0061832.1.gif-high.gif

 

1   Straight mounted

2   Mounted with angle gearbox, rotatable 4 x 90°