IF_RobotPSeriesCalibration - Stop (Method)

Overview

Type:

Method

Available as of:

V1.0.0.0

Versions:

Current version

This chapter provides information on:

Task

Stop the ongoing calibration mode.

Description

By calling up the method, while BrakeRelease is active, the released brakes will be closed.

By calling up the method, while a motion is active (OnTorque, MoveToCheckPosition or MoveToMountPosition), the motion will be stopped.

Interface

Output

Data type

Description

q_etDiag

GD.ET_Diag

General, library-independent statement on the diagnostic.

A value not equal to ET_Diag.Ok corresponds to a diagnostic message.

q_etDiagExt

ET_DiagExt

POU-specific output for the diagnostic.

q_etDiag = ET_Diag.Ok -> Status message

q_etDiag <> ET_Diag.Ok -> Diagnostic message

q_sMsg

STRING[80]

Event-triggered message that gives additional information on the diagnostic state.

Diagnostic Messages

q_etDiag

q_etDiagExt

Enumeration value

Description

OK

Ok

0

Successful

ExecutionAborted

MissingProgramCall

32

The program call is unavailable.

MissingProgramCall

Enumeration name:

MissingProgramCall

Enumeration value:

32

Description:

The program call is unavailable.

Issue

Cause

Solution

Call calibration method was unsuccessful

The program SR_SlowCyclicExecution is not called in a cyclic task.

Ensure that the program SR_SlowCyclicExecution is called in a cyclic task.

Ok

Enumeration name:

Ok

Enumeration value:

0

Description:

Successful

The calibration method was called successfully.