State

General

Type

AD

Devices supporting the parameter

SinCos Encoder Input

Traceable

Yes

Functional Description

Displays the availability and the validity of the encoder position data.

Value

Data type

Meaning

not ready / 0

DINT

The encoder or encoder processing is not ready.

Initialization / 1

DINT

Encoder processing is initialized.

not synchronous / 2

DINT

Encoder processing does not run synchronously with real-time processing (SERCOS bus is not in phase 4). The velocity and position values of the encoder are not exact and therefore cannot be used.

Read type / 3

DINT

The encoder type is read out.

ready / 10

DINT

The velocity and position values of the encoder are valid.

Read position / 11

DINT

The absolute position is read from the encoder.

Write position / 12

DINT

The absolute position is written into the encoder.

Read error code / 13

DINT

The error code is read from the encoder.