TransmissionTrigger (FB)

FUNCTION_BLOCK TransmissionTrigger EXTENDS CBM.ETrig

This function block triggers the transmission of a parameter group.

Note

The transmission is not done immediately. The function block only sets a flag in communication stack which causes a transmission in next bus cycle.

InOut:

Scope

Name

Type

Comment

Inherited from

Input

xExecute

BOOL

Rising edge: Action starts

Falling edge: Resets outputs

If a falling edge occurs before the function block has completed its action, the outputs operate in the usual manner and are only reset if either the action is completed or in the event of an error. In this case, the corresponding output values (xDone, xError) are present at the outputs for exactly one cycle.

ETrig

Output

xDone

BOOL

TRUE: Action successfully completed

ETrig

xBusy

BOOL

TRUE: Function block active

ETrig

xError

BOOL

TRUE: Error occurred, function block aborts action

FALSE: No error

ETrig

Input

itfParameterGroup

ITransmitParameterGroup

parameter group which should be transmitted.

Output

eError

ERROR

detailed error information if xError is TRUE.