ET_DiagExt

 

ET_DiagExt - General Information

Overview

Type:

List type

Available as of:

V1.0.0.0

Description

The enumeration ET_DiagExt specifies the POU-specific diagnostic and status messages.

Enumeration Elements

Name

Value

Description

Ok

0

Proceeding normally, satisfactory or under control, or other affirmative acknowledgement.

ReactionOffsetRange

1

ReactionOffset is outside of the valid range.

CmdUnknown

2

Command is indeterminable.

CmdImpossibleOverwrite

3

Command cannot be overwritten.

CmdImpossibleState

4

Command is impossible in this state.

CmdImpossibleReaction

5

Command is impossible due to an active error reaction.

DriveInvalid

6

Connected drive is invalid.

VelocityRange

7

Velocity is outside of the valid range.

AccelerationRange

8

Acceleration is outside of the valid range.

DecelerationRange

9

Deceleration is outside of the valid range.

JerkRange

10

Jerk is outside of the valid range.

MaxDistanceRange

11

MaxDistance is outside of the valid range.

MotionActiveVelLimitRange

12

MotionActiveVelLimit is outside of the valid range.

InverterEnableOff

13

InverterEnable is not set/ FALSE.

TorqueEnableOff

14

TorqueEnableOff is FALSE.

PowerSupplyNotFound

15

PowerSupply has not be found.

PowerSupplyInvalid

16

Connected PowerSupply is invalid.

PowerSupplyNotReady

17

Connected PowerSupply is not ready.

DriveError

18

Connected drive reported an unrecoverable exception.

DriveException

19

Connected drive reported an exception.

DriveWarning

20

Connected drive reported an advisory.

StateRange

21

State is outside of the valid range.

Working

22

In process.

MissingExtInit

23

The additional interface has not been correctly initialized.

GlobalSercosInterfaceInvalid

24

Global Sercos interface is invalid.

DiagExtRange

25

DiagExt ist outside of the valid range.

SubModuleAddInterfacesInvalidPointer

26

Invalid pointer to SubModuleAddInterfaces.

SubModuleConstantRange

27

SubModuleConstant is outside of the valid range.

StateUnexpected

28

State is unintended.

DriveNotReady

30

Connected drive is not ready for motion instructions.

UnexpectedFeedback

31

Unexpected feedback during execution.

AsyncStop

32

An asynchronous stop is being executed.

SyncStopEL

33

Synchronous stop – DriveEnable is FALSE.

SyncStopEH

34

Synchronous stop – DriveEnable is TRUE.

StopEndOfCycle

35

Stop at the end of program cycle.

Disabled

36

The POU is disabled.

Initializing

37

The POU is initializing.

NoOpDriveEnabled

38

No operating mode selected, DriveEnable is TRUE.

NoOpDriveDisabled

39

No operating mode selected, DriveEnable is FALSE.

ManualInit

40

Initialization of operating mode “Manual”.

SignalOriginInvalid

40

SignalOrigin is invalid.

ManualRunning

41

Executing operating mode “Manual”.

ManualExit

42

Exiting operating mode “Manual”.

AutomaticInit

43

Initialization of operating mode "Automatic".

AutomaticWaitForStart

44

Operating mode “Automatic” – waiting for start signal.

AutomaticStarting

45

Operating mode “Automatic” – Starting.

AutomaticRunning

46

Executing operating mode “Automatic”.

AutomaticExit

47

Exiting operating mode "Automatic".

BrakeReleaseInit

48

Initializing operating mode “BrakeRelease”.

BrakeClosed

49

Operating mode “BrakeRelease” – brake is closed.

BrakeReleased

50

Operating mode “BrakeRelease” – brake is open.

BrakeReleaseExit

51

Exiting operating mode “BrakeRelease”.

CurrentStandardItfInvalid

52

CurrentStandardItf is invalid.

CurrentAddItfInvalid

53

CurrentAddItfInvalid is invalid.

MotionActiveVelTypeRange

54

MotionActiveVelType is outside of the valid range.

OpModeRange

55

OpMode is outside of the valid range.

ParentInvalid

56

Parent is invalid.

ParentNotRegistered

57

Parent is not registered.

MaxNumberOfLoggerPointsExceeded

58

Maximum number of logger points was exceeded.

RadiusInvalid

59

Radius is invalid.

RadiusRange

60

Radius is outside of the valid range.

PreControllerModeInvalid

61

PreControllerMode is invalid.

ControllerModeInvalid

62

ControllerMode is invalid.

StartMovementModeInvalid

63

StartMovementMode is invalid.

SensorValueMinMaxInvalid

64

SensorValueMinMax is invalid.

ApplicationValueMinMaxInvalid

65

ApplicationValueMinMax is invalid.

ApplicationLevelRefRange

66

ApplicationLevelRef is outside of the valid range.

AnalogInputInvalid

67

AnalogInput is invalid.

MaxZoneRange

68

MaxZone is outside of the valid range.

MinZoneRange

69

MinZone is outside of the valid range.

FeedbackMinReached

71

FeedbackMin reached its limit.

FeedbackMaxReached

72

FeedbackMax reached its limit.

MaxStartDistanceRange

73

MaxStartDistance is outside of the valid range.

MaxStartDistanceReached

74

MaxStartDistance reached its limit.

MeasurementPeriodRange

75

MeasurementPeriod is outside of the valid range.

FoilWidthRange

76

FoilWidth is outside of the valid range.

FoilDensityRange

77

FoilDensity is outside of the valid range.

CoilRadiusRange

78

CoilRadius is out of range.

JLoadGainRange

79

JLoadGain is outside of the valid range.

NumberOfAsyncTasksRange

80

PDL.Gc_udiMaxNumOfAsyncTasks is outside of the valid range.

MaxNumberOfReusableObjectsExceeded

81

Maximum number of reusable objects has been exceeded.

MasterInvalid

82

Master is invalid.

SlaveMasterRatioRange

83

SlaveMasterRatio is outside of the valid range.

MiddlePosRangeRange

84

MiddlePosRange is outside of the valid range.

StartFillLevelRange

85

StartFillLevel is outside of the valid range.

DirectMasterInvalid

86

DirectMaster is invalid.

DisturbanceValueRange

87

DisturbanceValue is outside of the valid range.

StartThresholdRange

88

StartThreshold is outside of the valid range.

MasterStandStill

89

Master is at stand still while receiving feedback.

TimeOut

90

An operation timed out.

CommunicationNotPossible

91

Communication is not possible.

ParameterNotConfigured

92

Parameter is not configured.

DataSuccessfullyWritten

93

Data is sucessfully written.

WaitForCommunication

94

Wait for communication.

WaitUntilDiagnosticsManagerReady

95

Wait until diagnostics manager is ready.

WaitUntilDiagSourceRegistered

96

Wait until diagnostic source is registered.

WaitUntilDisabled

97

Wait until POU is disabled.

WritingToFile

98

Writing data to file.

FileIdInvalid

99

Id of file is invalid.

InvalidController

100

Controller is invalid.