OverloadDiagMsg

General

Type

EF

Offline editable

No

Devices supporting the parameter

PacDrive LMC x00C, PacDrive LMC x01C,

OnBoard I/O, DIO8 module

Traceable

Yes

Functional Description

The parameter is used to enter a bit to enable or disable the diagnostic message 8788 Wiring error detected with ext. diagnostic message Overload for this digital field output.

This bit in the parameter OverloadDiagMsg is assigned to a corresponding bit in the bitmask of the parameter OverloadDiagMsk. Modifications in the parameter OverloadDiagMsg are automatically written to the corresponding bit in the parameter OverloadDiagMsk and vice-versa. The last modification is active. Also see parameter OpenloadDiagMsg.

Value

Data type

Meaning

L / 0

UINT

The output does not report the diagnostic message 8788 Detected wiring error (Overload).

H / 1

UINT

The output reports the diagnostic message 8788 Detected wiring error (Overload).