Type |
AD |
|
Devices supporting the parameter |
Encoder network (Sync. Module and Synchronization slave) |
|
Traceable |
Yes |
Displays the synchronization status. The parameter State is to be seen analogously to the parameter State of the Synchronization master.
|
Value |
Data type |
Meaning |
|---|---|---|
|
disabled / 0 |
DINT |
The Synchronization slave is disabled. |
|
initialization / 1 |
DINT |
The Synchronization slave is being initialized and parameterized by the Synchronization master. Communication is still not cyclic. |
|
waiting for sync / 2 |
DINT |
Telegrams for controller synchronization are being transmitted cyclically. |
|
synchronized / 3 |
DINT |
Synchronization was successfully established with the Synchronization master. |
|
waiting for data / 4 |
DINT |
Waiting for cyclic encoder data. |
|
active / 5 |
DINT |
Communication with the Synchronization master is established and encoder data are being evaluated correctly. |
|
error / 6 |
DINT |
An error occurred, communication must be reestablished. |