Structure for the data of the electronic nameplate of a Sercos device received with FC_NameplateResponse after a request with FC_NameplateRequest.
|
Variable |
Data type |
Description |
|---|---|---|
|
sVendorName |
STRING(80) |
Vendor name of the device (parameter S-0-1300.x.02) |
|
wVendorCode |
WORD |
Vendor code of the device (parameter S-0-1300.x.03) . The vendor code is a unique number assigned to each vendor. |
|
sDeviceName |
STRING[80] |
Device name, manufacturer-specific (parameter S-0-1300.x.04) |
|
sVendorDeviceID |
STRING[80] |
Vendor device ID (parameter S-0-1300.x.05). The vendor device ID is a unique ID managed by the vendor. |
|
wFunctionRevision |
WORD |
Function revision of the device (parameter S-0-1300.x.07) |
|
sHWRevision |
STRING[80] |
Hardware revision of the device (parameter S-0-1300.x.08) |
|
sFWRevision |
STRING[80] |
Firmware version of the device (parameter S-0-1300.x.09) |
|
sFirmwareLoaderRevision |
STRING[80] |
Firmware loader or boot loader revision (parameter S-0-1300.x.10) |
|
sSerialNumber |
STRING[80] |
Serial number of the device (parameter S-0-1300.x.12) |
|
sManufacturingDate |
STRING[80] |
Date and time of manufacture of the device (parameter S-0-1300.x.13) |
|
dwOerationalHours |
DWORD |
Hours of operation of the device (parameter S-0-1300.x.20) |
|
sHostname |
STRING[80] |
Network hostname of the device (parameter S-0-1039) |
|
wNumberOfSlaves |
WORD |
Number of slaves connected to the device |