Before you configure the connection to the SQL database with the , make sure that you already executed the steps for establishing an SQL connection:
Step 1: Set up the PC on which you intend to install the SQL Gateway.
Step 2: Set up your SQL database.
Step 3: Install the SQL Gateway.
To configure a connection to an SQLite database, you first have to configure a general for specifying the server name and the server type. As the SQLite database file is saved locally on the SQL Gateway PC, there is no further configuration required for the server. In a second step, configure one or more to specific SQLite database files that are accessible via the .
This procedure describes how to define the access to an SQLite database server:
Step |
Action |
Remark |
---|---|---|
1 |
In the SQL Gateway, right-click the node in the tree structure on the left-hand side and execute the command . tab of the |
Result: A new subnode with a default name is created. |
2 |
Enter a unique in order to identify this database server. |
– |
3 |
Select from the list. |
Since SQLite database files are accessed directly without a database server, no further parameters need to be configured. Proceed with the configuration. |
This procedure describes how to create a connection to an SQLite database file:
Step |
Action |
Result/Remark |
---|---|---|
1 |
In the SQL Gateway, right-click the node in the tree structure on the left-hand side and execute the command . tab of the |
Result: A new subnode with a default name is created. |
2 |
Enter a unique in order to identify this database connection. |
Make sure that exactly the value of the parameter is used in the client configuration:The element wsDbConnectionName configured in the EcoStruxure Machine Expert SqlRemoteAccess library must have the identical value as the parameter . |
3 |
From the SQLite database server. list, select the |
The list contains entries for those servers that are defined under the node.After you have selected an SQLite database server as , the configuration parameters described in this chapter are displayed. |
4 |
Enter the path to the SQLite directly or click the button to browse the file system for the file. |
– |
5 |
Enter the SQLite database if the database is password-protected. to access the |
– |
6 |
In order to add further parameters to your SQLite database configuration, click the button and activate the parameters of your choice in the dialog box. |
Result: After you have confirmed your selection with , the selected parameters will be displayed in the editor and can be configured. |
7 |
Click the button in order to verify whether the connection to the database can be established with the parameters configured. |
Result: A message is displayed indicating the result of the test. For further information, refer to the Troubleshooting chapter. |