Components of the axis may be damaged or destroyed as a result of a collision.
|
FALLING OR EJECTED PARTS |
oThoroughly inspect all components of the axis and all components attached to the axis, including the motor and the gearbox, for damage after a collision. oDo not use the axis if any of the components are damaged or suspected to be damaged. |
Failure to follow these instructions can result in death, serious injury, or equipment damage. |
Step |
Action |
---|---|
1 |
Verify the components for completeness. If any components are missing, locate the same and remove them from the surrounding machinery. |
2 |
Replace damaged or missing components. |
Verifying the Elastomer Coupling (Optional Equipment)
Step |
Action |
---|---|
1 |
Remove the motor and/or the gearbox as described in . |
2 |
Verify the elastomer coupling by a visual inspection for damage. |
NOTE: A damaged elastomer coupling must be replaced. For detailed information, refer to .
In case of other repairs beyond those described in the present document, contact your local Schneider Electric service representative.