Type: |
Interface |
|
Available as of: |
V1.0.0.0 |
|
Inherits from: |
- |
This chapter provides information on:
This interface is part of IF_RobotFeedback and contains data on the motion of the robot in the Cartesian space.
|
Name |
Data type |
Accessing |
Description |
|---|---|---|---|
|
ifX |
Read |
Interface with return values for the motion of the TCP (Tool Center Point) along the X axis of the Cartesian coordinate system. |
|
|
ifY |
Read |
Interface with return values for the motion of the TCP along the Y axis of the Cartesian coordinate system. |
|
|
ifZ |
Read |
Interface with return values for the motion of the TCP along the Z axis of the Cartesian coordinate system. |
|
|
lrCurvature |
LREAL |
Read |
Curvature of the space movement.
|
|
lrRefAccelerationRadial |
LREAL |
Read |
Radial acceleration in the Cartesian space. SQRT(AccResultant² + AccTangential²) |
|
lrRefAccelerationResultant |
LREAL |
Read |
Resulting acceleration in the Cartesian space. SQRT(AccX² + AccY² + AccZ²) |
|
lrRefAccelerationTangential |
LREAL |
Read |
Tangential acceleration in the Cartesian space. |
|
lrRefVelocityTangential |
LREAL |
Read |
Tangential velocity in the Cartesian space. |
|
lrTrackingDeviation |
LREAL |
Read |
Resulting tracking error in the Cartesian space. SQRT(TDX² + TDY² + TDZ²)
NOTE:
This property is not supported by Modicon M262 Motion Controllers. |
|
rstTangent |
REFERENCE TO PDL.ST_Vector3D |
Read |
Tangent of the Cartesian position along the connected path (refer to Behavior of rstTangent (tangent vector feedback). |
|
rstEstimatedStopPosition |
REFERENCE TO PDL.ST_Vector3D |
Read |
Estimated Cartesian stop position on the connected path including a potential tracking (refer to Behavior of feedback property rstEstimatedStopPosition). |
|
xTrackingDeviationWarning |
BOOL |
Read |
TRUE = The parameterized maximum tracking error along the path is exceeded. FALSE = The parameterized maximum tracking error along the path is not exceeded. |