There are two ways of proceeding for handling and mounting of the robot. Study both ways of proceeding and determine which one is appropriate for your environment.
| WARNING | |
|---|---|
|
Step |
Action |
|---|---|
|
1 |
Using a forklift truck, lift the robot and the pallet into the enclosure.
|
|
2 |
Fasten the robot to the frame using the six provided counterbores (1). Size of the counterbore: M12 Tightening torque: 56 Nm (496 lbf-in) Property class of the screws: 8.8 or greater, or A2-70 or greater
|
|
3 |
Remove the cross piece cartons, the base carton and the plastic pallet from the robot. |
For information about the disposal of the packaging, refer to Disposal.
| WARNING | |
|---|---|
|
Step |
Action |
|---|---|
|
1 |
Pull two lifting lugs to the crane eyes at the mounting plate.
|
|
2 |
Use the crane to carefully lift the robot into the enclosure. |
|
3 |
Fasten the robot to the frame using the six provided counterbores (1). Size of the counterbore: M12 Tightening torque: 56 Nm (496 lbf-in) Property class of the screws: 8.8 or greater, or A2-70 or greater |