There are two ways to acknowledge diagnostic messages:
Function FC_DiagQuit()
| CAUTION | |
|---|---|
The capability to acknowledge the diagnostic message can be switched off with the function FC_DiagNoQuitSet(). If necessary, use the function FC_SysReset() or FC_PrgResetAndStart().
Acknowledging a diagnostic message does not eliminate the cause of the detected error. Acknowledgment serves to confirm that you have seen the message. When the diagnostic message has been acknowledged, it is deleted in the PacDrive system. If the cause of the diagnostic message remains, then that diagnostic message is re-detected in the PacDrive system.
With the following detected errors, it is also necessary to reset the triggering device for reasons of safety and due to the far reaching consequences of the detected error. This occurs with the reset button on the device or by cycling the control voltage of the device.
The following applies to the acknowledgement of diagnostic messages concerning the Multi carrier transport system (refer to table below):
YES in the Diag Quit column means that this diagnostic message can be acknowledged manually.
This can be done in EcoStruxure Machine Expert via , or with the function FC_DiagQuit().
YES in the Auto Quit column means that an attempt is made to reset this diagnostic message automatically on a Sercos run-up from CP0 to CP4 in the segment.
NO in both the Diag Quit column and the Auto Quit column means that this diagnostic message cannot be acknowledged at runtime of the segment. The segment stays in the error state until it is reset by power cycling the device.
|
Diagnostic code |
Diagnostic code message |
Diag Quit | Auto Quit |
|---|---|---|---|
|
8100 |
YES |
YES |
|
|
8101 |
YES |
YES |
|
|
8102 |
YES |
YES |
|
|
8106 |
YES |
NO |
|
|
8107 |
YES |
NO |
|
|
8108 |
YES |
YES |
|
|
8109 |
YES |
YES |
|
|
8111 |
YES |
YES |
|
|
8112 |
YES |
YES |
|
|
8123 |
YES |
NO |
|
|
8125 |
YES |
YES |
|
|
8126 |
YES |
YES |
|
|
8127 |
YES |
YES |
|
|
8132 |
YES |
YES |
|
|
8142 |
YES |
YES |
|
|
8161 |
YES |
YES |
|
|
8169 |
YES |
YES |
|
|
8183 |
NO |
NO |
|
|
8184 |
NO |
NO |
|
|
8185 |
NO |
NO |
|
|
8186 |
YES |
YES |
|
|
8551 |
YES |
YES |
|
|
8560 |
NO |
NO |
|
|
8561 |
YES |
YES |
|
|
8562 |
YES |
NO |
|
|
8563 |
YES |
YES |
|
|
8564 |
NO |
NO |
|
|
8565 |
NO |
NO |
|
|
8566 |
NO |
NO |
|
|
8567 |
YES |
YES |
|
|
8568 |
YES |
YES |
|
|
8569 |
YES |
NO |